欢迎访问ic37.com |
会员登录 免费注册
发布采购

M62281FP 参数 Datasheet PDF下载

M62281FP图片预览
型号: M62281FP
PDF下载: 下载PDF文件 查看货源
内容描述: 通用电流模式PWM控制IC [General Purpose Current Mode PWM Control IC]
分类和应用: 稳压器开关式稳压器或控制器电源电路开关式控制器光电二极管
文件页数/大小: 13 页 / 157 K
品牌: RENESAS [ RENESAS TECHNOLOGY CORP ]
 浏览型号M62281FP的Datasheet PDF文件第2页浏览型号M62281FP的Datasheet PDF文件第3页浏览型号M62281FP的Datasheet PDF文件第4页浏览型号M62281FP的Datasheet PDF文件第5页浏览型号M62281FP的Datasheet PDF文件第7页浏览型号M62281FP的Datasheet PDF文件第8页浏览型号M62281FP的Datasheet PDF文件第9页浏览型号M62281FP的Datasheet PDF文件第10页  
M62281P/FP
In the case that feed forward system by photo-coupler is applied, following two methods are available.
One is the method by error amp. as in figure 3-1, the other is by the direct connection to photo-coupler as in figure
3-2.
When photo-coupler is directly connected to EA OUT terminal, input terminal of error amp. is connected to GND,
photo-coupler is connected directly to EA OUT terminal.
V
CC
R1
Reference voltage (2.5 V)
R
IN
EA IN
R2
RF
+
EA
OUT
Figure 3-1 Method to Use Photo-Coupler (1)
Reference voltage (2.5 V)
+
EA IN
EA OUT
Figure 3-2 Method to Use Photo-Coupler (2)
In figure 3-1, AC gain is represented as :
A
V
 = 
RF
/
R
IN
Proper gain setting is about 40 dB.
RF should be 52 kΩ or more due to the current source capability of error amp.
R1, R2 should meet the condition as below so that the voltage of EA IN terminal should not be over 5 V.
R2
V
CC
/
(R1
+
R2)
5 V
Due to the input impedance of EA IN terminal, the current in R1, R2 should be less than several mA.
CT (OVP) Terminal
Timer type latch circuit works as follows.
Constant charge current flows out from CT terminal to the external capacitor when CLM is operative.
When the voltage of CT terminal rises up to over 4.0 V (Typ.), the latch circuit operates to make functions of this IC
inoperative. Inoperative status is sustained until supply voltage becomes less than stop voltage. The value for start-up
register has to be set so that the current over 1.8 mA (Typ.) can flow the resistor because the stop status has to be kept
by the current in start-up resistor R1 shown in application circuit.
When timer latch circuit is operative, supply current increases at high voltage as shown in figure 4 to avoid the damage
caused by unnecessarily in creased supply voltage.
Inoperative status goes back to operation by forcibly decreasing the voltage of CT terminal to less then 0.7 V.
REJ03D0840-0201 Rev.2.01 Nov 14, 2007
Page 6 of 12