M62009L/P/FP
Low Power 2 Output System Reset IC with External Input
REJ03D0782-0100
Rev.1.00
Sep 14, 2005
Description
As applications for microcomputers are increasing, a desire has arisen for a RAM backup function. Let us introduce
Renesas new low power dissipation, high-performance system reset IC, which is suitable for such RAM backup.
The M62009, which is a low power dissipation 2-output microcomputer system reset IC, is a 2-output system reset IC
which provides for RAM backup in microcomputers, and reduces power dissipation by using the Bi-CMOS process.
The M62009 considerably reduces the number of components in the reset circuit.
The M62009 performs two-step detection of normal supply voltage and backup supply voltage required for backup
mode. When the supply voltage is switched from normal supply voltage to backup supply voltage the interruption
output, which is one of the two outputs, gives the interruption signal to a microcomputer, in this way, the
microcomputer reduces power dissipation and enters in the backup mode. If the backup supply voltage goes lower than
the voltage required for backup, the reset output (RESET output) which is different from the
INT
output gives the reset
signal (forced reset) to the microcomputer. The interruption signal from the
INT
output recovers the microcomputer
from the backup mode. To recover from reset,
RESET
output is canceled when the specified interval of time (delay
time) elapses after the signal is given from the
INT
output.
Features
Bi-CMOS process realizes a configuration of low current dissipating circuits.
I
CC
= 7
µA
(Typ, normal mode, V
CC1
= V
CC2
= 5.0 V)
I
CC
= 5
µA
(Typ, backup mode, V
CC1
= 5.0 V)
I
CC
= 1
µA
(Typ, backup mode, V
CC1
= 2.5 V)
Two-step detection of supply voltage
V
CC1
(RESET):
V
S1-1
= 4.0 V (Typ, increase of V
CC1
)
V
S1-2
= 2.0 V (Typ, decrease of V
CC1
)
V
CC2
(INT):
Free setup
Two outputs (open drain type)
Reset output (RESET): Forced reset signal output
Interruption output (INT): Output of the signal for interruption processing (output of the switching signal for
backup mode)
Three types of outline packages
8-pin plastic SIP (single in-line package)
8-pin plastic DIP (dual in-line package)
8-pin plastic SOP (mini flat package)
Output based on RAM backup mode (see the timing chart)
Application
Prevention of errors in microcomputer system in electronic equipment that requires RAM backup, such as office,
industrial, and home-use equipment.
Rev.1.00 Sep 14, 2005 page 1 of 6