M61508FP
Connection of Data and Clock
CLOCK
D0
D1
D2
D3
D32
D33
D34
DATA
Latch signal "H"
Data signals are read at rising edges of Clock.
Latch signals are read at rising edges of Clock.
Digital Block Direct Current Characteristic
Limits
Item
Symbol
VIL
Min
0
Typ
Max
1.0
5.0
10
Unit
Test Conditions
VDD = 5 V setting
"L" Level Input Voltage
V
DATA, CLOCK Pin
"H" Level Input Voltage
"L" Level Input Electric Current
"H" Level Input Electric Current
VIH
IIL
4.0
–10
—
—
—
μA
V = 0 V
V = 5 V
DATA,
CLOCK Pin
IIH
10
REJ03F0203-0201 Rev.2.01 Mar 31, 2008