M52334FP
V18 RF AGC Operating Voltage
Input SG8 into VIF IN, and gradually reduce Vi and then measure the input level when RF AGC output TP14 reaches
1/2 V
CC
, as shown below.
TP18
Voltage
V
18H
1/2 V
CC
V
18L
Vi
Vi (dBµ)
CL-U Capture Range
1. Increase the frequency of SG9 until the VCO is out of locked-oscillation.
2. Decrease the frequency of SG9 and measure the frequency fU when the VCO locks.
CL-U
=
fU
−
45.75 (MHz)
CL-L Capture Range
1. Decrease the frequency of SG9 until the VCO is out of locked-oscillation.
2. Increase the frequency of SG9 and measure the frequency fL when the VCO locks.
CL-L
=
45.75
−
fL (MHz)
CL-T Capture Range
CL-T
=
CL-U
+
CL-L (MHz)
µAFT
Sensitivity, V
19H
AFT Maximum Voltage, V
19L
AFT Minimum Voltage
1. Input SG10 into VIF IN, and set the frequency of SG 10 so that the voltage of AFT output TP19 is 5 V. This
frequency is named f (3).
2. Set the frequency of SG10 so that the AFT output voltage is 4 V. This frequency is named f (2).
3. In the graph, maximum and minimum DC voltage are V
19H
and V
19L
, respectively.
Rev.2.00 Jun 14, 2006 page 6 of 18