MITSUBISHI MICROCOMPUTERS  
M37754M8C-XXXGP, M37754M8C-XXXHP  
M37754S4CGP, M37754S4CHP  
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER  
Three-phase mode 0  
Then, write “1” to the U-phase output polarity set buffer (bit 1 at ad-  
In selecting three-phase waveform mode, three-phase mode 0 is se-  
lected by setting bit 4 of the waveform output mode register (address  
1A16) to “0”.  
dress 1C16) before the counter of timer B2 becomes 000016.  
After that, when the counter of timer B2 becomes 000016, the  
timer A2 starts one-shot pulse output. Simultaneously, the con-  
tents of U-phase output polarity set buffer, “1” in this case, are set  
into the output polarity set toggle flip-flop 2 and the U phase wave-  
form remains “L” level.  
The output polarity of three-phase waveform depends on the output  
polarity set toggle flip-flop. The positive waveform of the three-phase  
waveform is “H” output when the toggle flip-flop is “0”; it is “L” output  
when the toggle flip-flop is “1”. (Three-phase waveform is output as  
a negative waveform.)  
When the one-shot pulse output of timer A2 is completed, the con-  
tents of output polarity set toggle flip-flop 2 is reversed from “1” to  
“0”. Simultaneously, the one-shot pulse output of the dead-time  
timer starts.  
Each output polarity set toggle flip-flop has the output polarity set  
buffer shown in Figure 44. When the timer B2’s counter contents be-  
come 000016, the contents of output polarity set buffer are set into  
the output polarity set toggle flip-flop. After that, the polarity of the  
contents of output polarity set toggle flip-flop are reversed each time  
completion of one-shot pulse of timer (timers A2 to A0) correspond-  
ing to each phase.  
When the contents of output polarity set toggle flip-flop 2 are re-  
versed from “1” to “0”, the U-phase waveform changes its output  
level from “L” to “H” without waiting for completion of the one-shot  
pulse output of the dead-timtimer.  
U-phase waveform is ged by repeating the operation  
Figure 45 shows an example of U-phase waveform and the output  
operation is explained. Three-phase mode 0 becomes valid when  
writing “0” to the U-phase output polarity set buffer (bit 1 at address  
1C16) and actuating the timer B2. When the counter of timer B2 be-  
comes 000016, the timer B2 interrupt request signal occurs and the  
timer A2 simultaneously starts one-shot pulse output. At this time,  
the contents of U-phase output polarity set buffer, “0” in this case, are  
set into the output polarity set toggle flip-flop 2.  
above. The way to ghase waveform, which is the  
negative phase of e same as that for U-phase wave-  
form except thas of output polarity set toggle flip-flop  
2 are treateersed signal from the case of U-phase  
wavefor
_
In thise waveform and U-phase waveform, having  
thhase of U-phase, are output from the pins so that  
ls do not overlap each other. The width of “L” level can  
modified by changing the value of timer B2 or timer A2.  
When the one-shot pulse output of timer A2 is completed, the con-  
tents of output polarity set toggle flip-flop 2 is reversed from “0” to “1
Simultaneously, the one-shot pulse of the 8-bit dead-time tim
_
__  
-phase waveform and V-, W-phase waveform, having their  
egative phase, are similarly output according to the correspond-  
ing timer operation.  
output for ensuring time not to overlap “L” levels of U phas
_
form and its negative U phase waveform.  
The explanation above is an example of three-phase waveform  
generating due to an triangular wave modulation. Three-phase  
waveform due to a saw-tooth-wave modulation can also be gen-  
erated by fixing each beginning level of phases.  
The U-phase waveform output keeps “H” level from the  
one-shot pulse output of the dead-time timer is cen if  
the contents of output polarity set toggle flip-floed from  
“0” to “1” owing to the timer A2’s one-shot . When the  
one-shot pulse output of the dead-time mpleted, “1” of  
output polarity set toggle flip-flop 2 een reversed be-  
comes valid and the U phase waves to “L” level.  
Signal output each time  
Timer B2 becomes 000016  
One-shot pulse output  
with timer A2  
Contents of output polarity  
set toggle flip-flop 2  
Reversed pulse output  
signal with dead-time timer  
U-phase waveform output  
U-phase waveform output  
Fig. 45 U-phase waveform output example in three-phase mode 0 (triangular wave modulation)  
39  