HD74AC244/HD74ACT244
DC Characteristics: HD74AC244
Item
Sym-
bol
V
IH
Vcc
(V)
3.0
4.5
5.5
V
IL
3.0
4.5
5.5
3.0
4.5
5.5
3.0
4.5
V
OL
5.5
3.0
4.5
5.5
3.0
4.5
Input leakage
current
3 State current
I
IN
I
OZ
5.5
5.5
5.5
min.
2.1
3.15
3.85
—
—
—
2.9
4.4
5.4
2.58
3.94
4.94
—
—
—
—
—
—
—
—
Ta = 25°C
°
typ.
1.5
2.25
2.75
1.50
2.25
2.75
2.99
4.49
5.49
—
—
—
0.002
0.001
0.001
—
—
—
—
—
max.
—
—
—
0.9
1.35
1.65
—
—
—
—
—
—
0.1
0.1
0.1
0.32
0.32
0.32
±0.1
±0.5
Ta = –40 to
+85°C
°
min.
2.1
3.15
3.85
—
—
—
2.9
4.4
5.4
2.48
3.80
4.80
—
—
—
—
—
—
—
—
max.
—
—
—
0.9
1.35
1.65
—
—
—
—
—
—
0.1
0.1
0.1
0.37
0.37
0.37
±1.0
±5.0
µA
µA
V
V
OUT
= 0.1 V or V
CC
–0.1 V
Unit
Condition
Input Voltage
V
V
OUT
= 0.1 V or V
CC
–0.1 V
Output voltage
V
OH
V
IN
= V
IL
or V
IH
I
OUT
= –50
µA
V
IN
= V
IL
or V
IH
I
OH
= –12 mA
I
OH
= –24 mA
I
OH
= –24 mA
V
IN
= V
IL
or V
IH
I
OUT
= 50
µA
V
IN
= V
IL
or V
IH
I
OL
= 12 mA
I
OL
= 24 mA
I
OL
= 24 mA
V
IN
= V
CC
or GND
V
IN(OE)
= V
IL
, V
IH
V
IN
= V
CC
or GND
V
OUT
= V
CC
or GND
V
OLD
= 1.1 V
V
OHD
= 3.85 V
V
IN
= V
CC
or ground
Dynamic output
current*
Quiescent supply
current
I
OLD
I
OHD
I
CC
5.5
5.5
5.5
—
—
—
—
—
—
—
—
8.0
86
–75
—
—
—
80
mA
mA
µA
*Maximum
test duration 2.0 ms, one output loaded at a time.
Recommended Operating Conditions: HD74ACT244
Item
Supply voltage
Input and output voltage
Operating temperature
Input rise and fall time
(except Schmitt inputs)
V
IN
0.8 to 2.0 V
Symbol
V
CC
V
I
, V
O
Ta
tr, tf
Ratings
2 to 6
0 to V
CC
–40 to +85
8
V
V
°C
ns/V
V
CC
= 4.5V
V
CC
= 5.5V
Unit
Condition
Rev.2.00, Jul.16.2004, page 3 of 8