HD26LS32A
Recommended Operating Conditions
Item
Supply Voltage
In Phase Input Voltage
Output Current
Operating Temperature
Symbol
V
CC
V
IC
I
OH
I
OL
Topr
4.75
—
—
—
0
Min
5.00
—
—
—
—
Typ
Max
5.25
±7.0
–440
8
70
V
V
µA
mA
°C
Unit
Electrical Characteristics
(Ta = 0 to +70°C)
Item
Differential Input High
Threshold Voltage
Differential Input Low
Threshold Voltage
Input Hysteresis*
2
Enable Input Voltage
Enable Input Clamp
Voltage
Output Voltage
Symbol
V
TH
V
TL
V
TH
– V
TL
V
IH
V
IL
V
IK
V
OH
V
OL
I
OZ
Min Typ*
1
Max
—
—
—
—
2.0
—
—
2.7
—
—
—
—
—
—
—
—
—
12
–15
—
—
—
50
—
—
—
—
—
—
—
—
—
—
—
—
—
15
—
0.2
–0.2
–0.2
—
—
0.8
–1.5
—
0.4
0.45
20
–20
1.2
–1.7
100
20
–0.36
—
–85
Unit
V
Conditions
V
IC
= –7 to +7 V V
OH
= 2.7V, I
OH
= –440 µA
V
OL
= 0.4 V, I
OL
= 4 mA
V
OL
= 0.45 V, I
OL
= 8 mA
mV
V
V
CC
= 4.75 V, I
IN
= –18 mA
V
CC
= 4.75 V
V
IL
(G) = 0.8 V
µA
V
CC
= 5.25 V
V
ID
= 1 V, I
OH
= –440 µA
V
ID
= –1 V, I
OL
= 4 mA
V
ID
= –1 V, I
OL
= 8 mA
V
O
= 2.4 V
V
O
= 0.4 V
Off State (High
Impedance) Output
Current
Line Input Current
Enable Input Current
II
I
I
(EN)
I
IH
I
IL
ri
I
OS
*
3
mA
µA
mA
kΩ
mA
Input Resistance
Short Circuit Output
Current
Supply Current
I
CC
—
52
70
V
CC
= 5.25 V, V
I
= 0 V (All Outputs Disable)
Notes: 1. All typical values are at V
CC
= 5 V, Ta = 25°C,V
IC
= 0.
2. Hysteresis is the differential between the positive going input threshold voltage and the negative going input
threshold voltage.
3. Not more than one output should be shorted at a time.
V
I
= 15 V, Other Inputs –10 to +15 V
V
I
= –15 V, Other Inputs –15 to +10 V
V
I
= 5.5 V
V
I
= 2.7 V
V
I
= 0.4 V
V
IC
= –15 to +15 V (Other Inputs AC GND)
V
CC
= 5.25 V
Switching Characteristics
(V
CC
= 5 V, Ta = 25°C)
Item
Propagation Delay Time
Output Enable Time
Output Disable Time
Symbol
t
PLH
t
PHL
t
ZH
t
ZL
t
HZ
t
LZ
—
—
—
—
—
—
Min
20
22
17
20
21
30
Typ
Max
35
35
22
25
30
40
ns
ns
ns
Unit
Conditions
C
L
= 15 pF
C
L
= 15 pF
C
L
= 5 pF
Rev.2.00, Jul.16.2004, page 3 of 7