HA12187FP
Absolute Maximum Ratings
(Ta = 25°C)
Item
Symbol
Ratings
Power-supply voltage
V
CC
7
Allowable power dissipation
Pd
400
Operating temperature
Topr
–40 to 85
Storage temperature
Tstg
–55 to 125
Input voltage
Vin
–1.0 to 6.7
Bus input voltage
Bus
18
Note: Recommended operating power supply voltage range: 5 V
±0.5
V
Unit
V
mW
°C
°C
V
V
Notes
Ta
≤
85°C
Electrical Characteristics
(V
CC
= 5.0 V, Ta = 25°C)
Item
S1
Symbol Min
Typ Max Unit
Test Conditions
3.5
—
—
V
High-level input V
IHS1
V1 = 0 V
→
5 V, V3 = 0 V
voltage
With the potential difference
between pin 5 and pin 6 120
mV or more
Low-level input V
ILS1
voltage
—
—
1.5
V
V1 = 5 V
→
0 V, V3 = 0 V
With the potential difference
between pin5 and pin 6 20
mV or less
V1 = 5 V, V3 = 0 V
V1 = 0 V, V3 = 0 V
V3 = 0 V
→
5 V, V1 = 0 V
With the potential difference
between pin 5 and pin 6 120
mV or more
V3 = 5 V
→
0 V, V1 = 0 V
With the potential difference
between 5 and pin 6 20 mV
or less
V1 = 0 V, V3 = 5 V
V1 = 0 V, V3 = 0 V
I
OH
= | V
OHD+
– V
OHD–
| / 62
Ω
Pin 5 voltage = V
OP–
I
OL
= | V
OP+
– V
OP–
| / RI
V1 = 0 V, V3 = 0 V
Test
Pin
1
Test
Circuit
Figure 1
1
High-level input I
IHS1
current
Low-level input I
ILS1
current
S2
High-level input V
IHS2
voltage
—
—
3.5
—
—
—
1
1
—
µA
µA
V
1
1
3
Figure 1
Low-level input V
ILS2
voltage
—
—
1.5
V
3
High-level input I
IHS2
current
Low-level input I
ILS2
current
Driver
High-level
output current
I
OH
—
—
3.0
—
—
—
3.8
—
1
1
4.8
1
µA
µA
mA
µA
3
3
5, 6
5, 6
Figure 1
I
OL
Low-level
output leakage
current
V
OP+
Reference
operating
voltage (+)
V
OP–
Reference
operating
voltage (–)
Current drain 1
I
CC
H
Current drain 2
I
CC
L
2.3
2.5
2.7
V
6
2.3
2.5
2.7
V
V1 = 0 V, V3 = 0 V
5
5.5
1.7
7.3
2.2
9.5
2.7
mA
mA
V1 = 5 V, V3 = 0 V
V1 = 0 V, V3 = 0 V
7
7
Figure 1
Figure 1
Rev.2.00 Jun 15, 2005 page 4 of 21