TIMER B
8.5 Pulse period/pulse width measurement mode
Count source
Measurement pulse
FFFF16
Undefined
value
000016
Time
Transferred
(undefined value)
Transferred
(measured value)
Reload register
Counter
Transfer timing
✕
✕
Timing at which counter is
cleared to “000016
”
Count start bit
Timer Bi interrupt
request bit
Cleared to “0” when interrupt request is accepted or
cleared to “0” by software.
Undefined
Cleared to “0” by software.
✕ Counter is initialized by the first valid edge.
✕ Counter overflows.
✕The above applies when measurement is performed for an interval from one falling edge to the next
falling edge of the measurement pulse.
Fig. 8.5.5 Operation examples during pulse period measurement (when free-run count type is selected)
7906 Group User’s Manual Rev.2.0
8-26