RC4190  
PRODUCT SPECIFICATION  
3. Note the approximate air gap at I  
for the selected  
Compare the waveform you see to those pictured in  
Figure 28.  
MAX  
core, and order the core with the gap. (If the gapping is  
done by the user, remember that a washer spacer results  
in an air gap of twice the washer thickness, because two  
gaps will be created, one at the center post and one at the  
rim, like taking two bites from a doughnut.)  
Check for saturation at the highest expected ambient  
temperature.  
7. After the operation in circuit has been checked,  
reassemble and pot the core using a potting compound  
recommended by the manufacturer.  
4. If the required inductance is equal to the indicated value  
on the graph, then wind the core with the number of  
turns shown in table of sizes. The turns given are the  
maximum number for that gauge of wire that can be  
easily wound in the cores winding area.  
If the core material differs greatly in magnetic character-  
istics from the standard power material shown in Figure  
22, then the following general equation can be used to  
help in winding and gapping. This equation can be used  
for any core geometry, such as an E-E core.  
5. If the required inductance is less than the value indicated  
on the graph, a simple calculation must be done to find  
(1.26)(N2)(Ae)(108)  
LX = -----------------------------------------------------  
g = (le) ⁄ (ue)  
the adjusted number of turns. Find A (inductance  
L
index) for a specific air gap.  
L(indicated)  
Where: N = number of turns  
--------------------------------- = AL  
Turns2  
Ae = core area from data sheet (in cm2)  
le = magnetic path length from data sheet (in cm)  
ue = permeability of core from manufacturer's graph  
g = center post air gap (in cm)  
in Henrys/turn2  
Then divide the required inductance value by A to give  
L
the actual turns squared, and take the square root to find  
the actual turns needed.  
Manufacturers  
Below is a list of several pot core manufacturers:  
L(required)  
ActualTurns = ------------------------------  
AL  
Ferroxcube Company  
5083 Kings Highway  
Saugerties, NY 12477  
If the actual number of turns is significantly less than the  
number from the table then the wire size can be  
increased to use up the left-over winding area and  
reduce resistive losses.  
Indiana General Electronics  
Keasley, NJ 08832  
6. Wind and gap the core as per calculations, and measure  
the value with an inductance meter. Some adjustment of  
the number of turns may be  
Siemens Company  
186 Wood Avenue South  
Iselin, NJ 08830  
necessary.  
The saturation characteristics may be checked with the  
inductor wired into the switching regulator application  
circuit. To do so, build and power up the circuit. Then  
(recommend Tektronix P6042 or equivalent) around the  
inductor lead and monitor the current in the inductor.  
Draw the maximum load current from the application  
circuit so that the regulator is running at close to full  
duty cycle.  
Stackpole Company  
201 Stackpole Street  
St. Mary, PA 15857  
TDK Electronics  
13-1-Chome  
Nihonbaski, Chuo-ku, Tokyo  
Improper Operation  
(Waveform is Nonlinear, Inductor  
Is Saturating)  
Proper Operation  
(Waveform is Fairly Linear)  
I
MAX  
I
MAX  
0
0
65-3464-08  
Figure 28. Inductor Current Waveforms  
21  