MIL-M-38510/112B
TABLE II. Electrical test requirements.
Subgroups (see table III)
Class S
Class B
devices
devices
1
1*, 2, 3, 4
1, 2, 3, 4, 5,
6, 7, 8, 9
1, 2, 3 and
table IV delta
limits
1, 2, 3 and
table IV delta
limits
1, 2, 3
1
1*, 2, 3, 4
1, 2, 3, 4, 5,
6, 7, 8, 9
N/A
1 and table
IV delta
limits
1
MIL-PRF-38535
test requirements
Interim electrical parameters
Final electrical test parameters
Group A test requirements
Group B electrical test parameters when
using the method 5005 QCI option
Group C end-point electrical parameters
Group D end-point electrical parameters
*PDA applies to subgroup 1 (see 4.3c).
4. VERIFICATION.
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or
as modified in the device manufacturer’s Quality Management (QM) plan. The modification in the QM plan shall not
effect the form, fit, or function as function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38535, and shall be conducted on all devices prior
to qualification and quality conformance inspection. The following additional criteria shall apply:
a.
The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as specified
in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be
maintained under document control by the device manufacturer's Technology Review Board (TRB) in
accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon
request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in
accordance with the intent specified in test method 1015 of MIL-STD-883.
Interim and final electrical test parameters shall be as specified in table II, except interim electrical
parameters test prior to burn-in is optional at the discretion of the manufacturer.
Reverse bias burn-in (method 1015 of MIL-STD-1835) required on class S devices only.
Additional screening for space level product shall be as specified in MIL-PRF-38535.
b.
c.
d.
4.3 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.
7