 浏览型号M38510/11005BCX的Datasheet PDF文件第9页浏览型号M38510/11005BCX的Datasheet PDF文件第10页浏览型号M38510/11005BCX的Datasheet PDF文件第11页浏览型号M38510/11005BCX的Datasheet PDF文件第12页浏览型号M38510/11005BCX的Datasheet PDF文件第14页浏览型号M38510/11005BCX的Datasheet PDF文件第15页浏览型号M38510/11005BCX的Datasheet PDF文件第16页浏览型号M38510/11005BCX的Datasheet PDF文件第17页  
MIL-M-38510/110C  
TABLE I. Electrical performance characteristics – Continued.  
Conditions  
-55°C T +125°C  
Group A  
subgroups  
Device  
type  
Limits  
Max  
Unit  
A
Test  
Symbol  
CS  
see figure 2  
unless otherwise specified  
Min  
80  
Channel separation  
7
01,02,  
03,04,  
05,06,  
07,08  
dB  
T = +25°C,  
A
see figure 7  
1/ Device types 01 to 04 shall be tested at V  
= 0 V, +15 V, and –15 V with ±V  
CC  
= ±20 V; and at V  
= 0 V with  
CM  
CM  
±V  
CC  
= ±5 V. Device types 05 and 06 should be tested at V  
= –13 V with V  
= 2 V and -V  
CC  
= -28 V;  
CM  
CC  
V
= +15 V with +V  
= 30 V and -V  
= 0 V; V  
CM  
= +1.4 V with V  
= 5 V and -V  
= 0 V;  
CM  
CM  
CC  
CC  
CC  
CC  
V
= –1.1 V at ±V  
CC  
= 2.5 V.  
2/ CMR is determined by measuring input offset voltage as follows:  
Offset voltage  
condition  
Device types  
Units  
01 - 04  
05 and 06  
+V  
CC  
35  
5
-V  
V
15  
-15  
+V  
CC  
30  
2
-V  
CC  
0
-28  
V
O
15  
-13  
CC  
-5  
-35  
O
1
2
V
V
3/ Continuous limits will be considerably lower and apply for –55°C T 25°C.  
A
4/ I  
5/ I  
and I  
limits for device type 01 only at T = -55°C are –75 mA and 75 mA respectively.  
SO(-) A  
SO(+)  
limits are the total for all four amplifiers at no load, connected as grounded followers.  
CC  
6/ AVS(+) for device types 05 and 06 only.  
7/ Device types 05 and 06 transient response is specified with the input pulse referenced to 5 V. For application  
purposes the device may be operated with the input referenced to ground, however, saturation effects will cause  
the response time to increase by approximately 50 percent.  
13