FM32L278/L276/L274/L272 - 3V I2C Companion  
By convention, any device that is sending data onto  
the bus is the transmitter while the target device for  
this data is the receiver. The device that is  
controlling the bus is the master. The master is  
responsible for generating the clock signal for all  
operations. Any device on the bus that is being  
controlled is a slave. The FM32L27x is always a  
slave device.  
Two-wire Interface  
The FM32L27x employs an industry standard two-  
wire bus that is familiar to many users. This product  
is unique since it incorporates two logical devices in  
one chip. Each logical device can be accessed  
individually. Although monolithic, it appears to the  
system software to be two separate products. One is  
a memory device. It has a Slave Address (Slave ID =  
1010b) that operates the same as a stand-alone  
memory device. The second device is a real-time  
clock and processor companion which have a unique  
Slave Address (Slave ID = 1101b).  
The bus protocol is controlled by transition states in  
the SDA and SCL signals. There are four conditions:  
Start, Stop, Data bit, and Acknowledge. The figure  
below illustrates the signal conditions that specify  
the four states. Detailed timing diagrams are shown  
in the Electrical Specifications section.  
SCL  
SDA  
7
6
0
Stop  
Start  
Data bits  
(Transmitter)  
Data bit Acknowledge  
(Transmitter) (Receiver)  
(Master) (Master)  
Figure 9. Data Transfer Protocol  
Start Condition  
Acknowledge  
A Start condition is indicated when the bus master  
drives SDA from high to low while the SCL signal is  
high. All read and write transactions begin with a  
Start condition. An operation in progress can be  
aborted by asserting a Start condition at any time.  
Aborting an operation using the Start condition will  
ready the FM32L27x for a new operation.  
The Acknowledge (ACK) takes place after the 8th  
data bit has been transferred in any transaction.  
During this state the transmitter must release the  
SDA bus to allow the receiver to drive it. The  
receiver drives the SDA signal low to acknowledge  
receipt of the byte. If the receiver does not drive  
SDA low, the condition is a No-Acknowledge  
(NACK) and the operation is aborted.  
If the power supply drops below the specified VTP  
during operation, any 2-wire transaction in progress  
will be aborted and the system must issue a Start  
condition prior to performing another operation.  
The receiver might NACK for two distinct reasons.  
First is that a byte transfer fails. In this case, the  
NACK ends the current operation so that the part can  
be addressed again. This allows the last byte to be  
recovered in the event of a communication error.  
Stop Condition  
A Stop condition is indicated when the bus master  
drives SDA from low to high while the SCL signal is  
high. All operations must end with a Stop condition.  
If an operation is pending when a stop is asserted,  
the operation will be aborted. The master must have  
control of SDA (not a memory read) in order to  
assert a Stop condition.  
Second and most common, the receiver does not  
send an ACK to deliberately terminate an operation.  
For example, during a read operation, the FM32L27x  
will continue to place data onto the bus as long as the  
receiver sends ACKs (and clocks). When a read  
operation is complete and no more data is needed,  
the receiver must NACK the last byte. If the receiver  
ACKs the last byte, this will cause the FM32L27x to  
attempt to drive the bus on the next clock while the  
master is sending a new command such as a Stop.  
Data/Address Transfer  
All data transfers (including addresses) take place  
while the SCL signal is high. Except under the two  
conditions described above, the SDA signal should  
not change while SCL is high.  
Rev. 3.0  
Feb. 2009  
Page 11 of 21