FM24CL16
Electrical Specifications
Absolute Maximum Ratings
Symbol
Description
V
DD
Power Supply Voltage with respect to V
SS
V
IN
Voltage on any pin with respect to V
SS
T
STG
T
LEAD
V
ESD
Storage Temperature
Lead temperature (Soldering, 10 seconds)
Electrostatic Discharge Voltage
- Human Body Model
(JEDEC Std JESD22-A114-B)
- Machine Model
(JEDEC Std JESD22-A115-A)
Package Moisture Sensitivity Level
Ratings
-1.0V to +5.0V
-1.0V to +5.0V
and V
IN
< V
DD
+1.0V
-40°C to + 125°C
300° C
4kV
300V
MSL-1
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This
is a stress rating only, and the functional operation of the device at these or any other conditions above those
listed in the operational section of this specification is not implied. Exposure to absolute maximum ratings
conditions for extended periods may affect device reliability.
DC Operating Conditions
(T
A
= -40° C to + 85° C, V
DD
=2.7V to 3.65V unless otherwise specified)
Symbol
Parameter
Min
Typ
Max
Units
V
DD
Main Power Supply
2.7
3.65
V
I
DD
VDD Supply Current
75
@ SCL = 100 kHz
µA
200
@ SCL = 400 kHz
µA
450
@ SCL = 1 MHz
µA
I
SB
Standby Current
1
µA
I
LI
Input Leakage Current
±1
µA
I
LO
Output Leakage Current
±1
µA
V
IH
Input High Voltage
0.7 V
DD
V
DD
+ 0.5
V
V
IL
Input Low Voltage
-0.3
0.3 V
DD
V
V
OL
Output Low Voltage
@ I
OL
= 3.0 mA
0.4
V
R
IN
WP Input Resistance (WP)
For V
IN
= V
IL
(max)
50
KΩ
For V
IN
= V
IH
(min)
1
MΩ
V
HYS
Input Hysteresis
(Does not apply to WP)
0.05 V
DD
V
Notes
1
2
3
3
5
4
Notes
1. SCL toggling between V
DD
-0.3V and V
SS
, other inputs V
SS
or V
DD
-0.3V.
2. SCL = SDA = V
DD
. All inputs V
SS
or V
DD
. Stop command issued.
3. V
IN
or V
OUT
= V
SS
to V
DD
. Does not apply to pins with pull down resistors.
4. This parameter is characterized but not tested.
5. The input pull-down circuit is strong (50KΩ) when the input voltage is below V
IL
and much weaker (1MΩ)
when the input voltage is above V
IH
.
Rev 3.3
Nov. 2005
Page 8 of 13