© Quantum Research Group Ltd.
Put Mode
Get Mode
Operand
Range
Bytes
Scope returned
Return
range
Default
setting
Char Hex
Name
Description
P/G Scope Bytes/Put
Returns
Page
Setup Commands
Signal threshold; fewer counts = more sensitive
4, 5, 6, 7, 8, 10, 12, 15, 17, 20, 25, 30, 35, 45, 55, 64
^A
^B
^C
^D
^E
^F
^G
0x01
0x02
0x03
0x04
0x05
0x06
0x07
Negative threshold
Positive threshold
Negative hysteresis
Positive hysteresis
Dwell time
P/G 1, 8, 64
P/G 1, 8, 64
2
2
2
2
2
2
2
0x04..0x40
0x04..0x40
0x00..0x03
0x00..0x03
0x01
0x01
0x02
0x03
0x04
0x05
0x06
0x07
1
1
1
1
1
1
1
1
1
0x04..0x40
0x04..0x40
0x0C
0x08
24
24
25
25
25
25
25
sensitivity to positive signals for recalibration
4, 5, 6, 7, 8, 10, 12, 15, 17, 20, 25, 30, 35, 45, 55, 64
hysteresis for negative threshold
50%, 25%, 12.5%, 0%
P/G
P/G
P/G
64
64
64
1
0x00..0x03 0x01 (25%)
0x00..0x03 0x01 (25%)
hysteresis for positive threshold
50%, 25%, 12.5%, 0%
1
delay from the rise of an X line to end of Y-gate;
only setting is 0x01 (167ns/period @ 6MHz Xtal)
64
1
0x01
0x01
0x0C
sets number of QT cycles / burst; zero disables burst
0, 1, 2, 3, 4, 5, 7, 10, 12, 15, 20, 25, 30, 40, 50, 64
Burst length
P/G 1, 8, 64
P/G 64
0x00..0x40
0x00..0x05
0x01..0x40
0x00..0x05
time from start of one burst to start of next burst
250us, 300us, 400us, 500us, 1000us, 2000us
0x01
(300us)
Burst spacing
64
rate of drift compensation for negative signal swings
0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0, 1.2, 1.5,
2.0, 2.5, 3.3, 4.5, 6.0, 7.5, 10 secs
^H
^I
0x08
0x09
Neg drift comp rate
Pos drift comp rate
P/G 1, 8, 64
P/G 1, 8, 64
2
2
0x01..0x64
0x01..0x64
0x08
0x09
1
1
1
1
0x01..0x64
0x01..0x64
0x1E (3s)
0x0A (1s)
26
26
rate of drift compensation for positive signal swings
0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0, 1.2, 1.5,
2.0, 2.5, 3.3, 4.5, 6.0, 7.5, 10 secs
number of detections required to register a touch,
counted in bursts of detection; zero disables a key.
0, 1, 2, 3, 5, 7, 10, 15, 20, 32,
^J
^K
^L
0x0A
0x0B
0x0C
Neg det int limit
Pos recal delay
Neg recal delay
P/G 1, 8, 64
P/G 1, 8, 64
P/G 1, 8, 64
2
2
2
0x00..0xFF
0x00..0xFF
0x00..0xFF
0x0A
0x0B
0x0C
1
1
1
1
1
1
0x00..0xFF
0x00..0xFF
0x00..0xFF
0x03
26
26
26
45, 60, 90, 123, 175, 255 counts
time required to trigger a recal from a positive signal
excursion in 0.1s increments; zero disables recal.
0, 0.1, 0.2, 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 3.2,
4.5, 6, 9, 12.3, 17.5, 25.5 secs
0x0A (1s)
0x3C (9s)
time required to trigger a recal from a detection, in 0.1s
increments. Zero disables recal.
0, 0.1, 0.2, 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 3.2,
4.5, 6, 9, 12.3, 17.5, 25.5 secs
period of QT pulses, in microseconds
2, 3, 4, 5, 6, 7, 8, 9, 10us
^M
^N
0x0D
0x0E
Intra-burst spacing
Pos error band
P/G
P/G
P/G
64
64
64
2
2
0x02..0x0A
0x00..0x64
0x0D
0x0E
64
64
1
1
0x02..0x0A
0x00..0x64
0x02
27
27
tolerable positive reference deviation with respect to
Locked reference values, step 10%. Zero disables.
0 (off)
tolerable negative reference deviation with respect to
Locked reference values, step 1%. Zero disables.
^O
^P
0x0F
0x10
Neg error band
Key suppression
2
2
0x00..0x63
0x00, 0x01
0x0F
0x10
64
1
1
1
0x00..0x63
0x00, 0x01
0 (off)
0 (off)
27
27
adjacent key suppression feature; 1 = on
P/G 1, 8, 64