4.2.1
Current Measurement Conditions
Legend: A = Activate, R = Read, RA = Read with Autoprecharge, P = Precharge, N = NOP or DESELECT
I
DD1: Operating Current: One Bank Operation
1. General test condition
a) Only one bank is accessed with tRC,MIN
.
b) Burst Mode, Address and Control inputs are changing once per NOP and DESELECT cycle.
c) 50% of data changing at every transfer
d) IOUT = 0 mA.
2. Timing patterns
a) DDR333B (166 MHz, CL = 2.5): tCK = 6 ns, BL = 4, tRCD = 3 × tCK, tRC = 9 × tCK, tRAS = 5 × tCK
Setup: A0 N N R0 N P0 N N N
Read: A0 N N R0 N P0 N N N - repeat the same timing with random address changing
b) DDR400B (200 MHz, CL = 3): tCK = 5 ns, BL = 4, tRCD = 3 × tCK, tRC = 11 × tCK, tRAS = 8 × tCK
Setup:A0 N N R0 N N N N P0 N N
Read: A0 N N R0 N N N N P0 N N -repeat the same timing with random address changing
I
DD7: Operating Current: Four Bank Operation
1. General test condition
a) Four banks are being interleaved with tRCMIN
.
b) Burst Mode, Address and Control inputs on NOP edge are not changing.
c) 50% of data changing at every transfer
d) IOUT = 0 mA.
2. Timing patterns
a) DDR333B (166 MHz, CL = 2.5): tCK = 6 ns, BL = 4, tRRD = 2 × tCK, tRCD = 3 × tCK, tRAS = 5 × tCK
Setup: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3
Read: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 - repeat the same timing with random address changing
b) DDR400B (200 MHz, CL = 3): tCK = 5 ns, BL = 4, tRRD = 2 × tCK, tRCD = 3 *× tCK, tRAS = 8 × tCK
Setup: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 N
Read: A0 N A1 RA0 A2 RA1 A3 RA2 N RA3 N - repeat the same timing with random address
Rev. 1.3, 2006-12
29
03292006-W2FE-ELDX