P4C422
MAXIMUM RATINGS(1)
Symbol
Parameter
Value
Unit
Symbol
Parameter
Value
Unit
VCC
Power Supply Pin with
Respect to GND
–0.5 to +7
V
TBIAS
Temperature Under
Bias
–55 to +125 °C
Terminal Voltage with
Respect to GND
(up to 7.0V)
–0.5 to
VCC +0.5
TSTG
IOUT
Storage Temperature
DC Output Current
–65 to +150 °C
VTERM
TA
V
20
mA
Operating Temperature –55 to +125 °C
CAPACITANCES(4)
(VCC = 5.0V, TA = 25°C, f = 1.0MHz)
RECOMMENDED OPERATING CONDITIONS
(2)
Symbol
CIN
Parameter
Conditions Typ. Unit
Grade
Commercial
Military
Ambient Temp
0°C to 70°C
Gnd
Vcc
Input Capacitance VIN = 0V
Output Capacitance VOUT = 0V
5
7
pF
pF
0V 5.0V ±10%
0V 5.0V ±10%
–55°C to 125°C
COUT
DC ELECTRICAL CHARACTERISTICS
Over recommended operating temperature and supply voltage(2)
P4C422
Symbol
Parameter
Test Conditions
Unit
Min
Max
VOH
VOL
VIH
VIL
VCL
IIX
Output High Voltage
Output Low Voltage
Input High Voltage
Input Low Voltage
IOH = –5.2 mA, VCC = Min.2.4
IOL = +8 mA, VCC = Min.
V
0.4
V
V
2.1
0.8
V
Input Clamp Diode Voltage IIN = –10 mA
–1.5
–10
–10
V
Input Load Current
GND≤ VIN ≤ VCC
OL ≤ VOUT ≤ VOH , Output Disabled
VCC= Max., VOUT = GND
10
10
90
µA
µA
mA
IOZ
IOS
Output Current (High Z)
V
Output Short Circuit
Current(3)
POWER DISSIPATION CHARACTERISTICS VS. SPEED
Temperature
Symbol
Parameter
Unit
-12
-15
-20
-25
-35
Range
-10
ICC
Dynamic Operating Current
Commercial
Military
90
N/A
90
N/A
90
90
90
90
65
90
65
90
mA
mA
Notes:
1. Stresses greater than those listed under MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification
is not implied. Exposure to MAXIMUM rating conditions for extended
periods may affect reliability.
2. Extended temperature operation guaranteed with 400 linear feet per
minute of air flow.
3. For test purposes, not more than one output at a time should be
shorted. Short circuit test duration should not exceed 30 seconds.
4. This parameter is sampled and not 100% tested.
5. Transition time is ≤ 3ns for 10, 12, and 15 ns products and ≤ 5ns for
20, 25, and 35 ns products, see Fig 1d. Timing is referenced at input
and output levels of 1.5V. The output loading is equivalent to the
specified IOL/IOH with a load capacitance of 15 pF (10, 12) or 30 pF (15,
20, 25, 35) as in Fig. 1a and 1b respectively.
6. Transition time is ≤ 3ns for 10, 12, and 15 ns products and ≤ 5ns for
20, 25, and 35 ns products, see Fig 1d. Transition is measured at
steady state HIGH level -500mV or steady state LOW level +500mV
on the output from a level on the input with load shown in Fig. 1c.
7. tW is measured at tWSA = min.; tWSA is measured at tW = min.
Document # SRAM101 REV. A
Page 2 of 10