P4C1048L
READ CYCLE NO. 2 (ADDRESS CONTROLLED)
READ CYCLE NO. 3 (CE CONTROLLED)
Notes:
1. WE is HIGH for READ cycle.
4. Transition is measured ± 200 mV from steady state voltage prior to change,
with loading as specified in Figure 1. This parameter is sampled and not
100% tested.
5. READ Cycle Time is measured from the last valid address to the first
transitioning address.
2. CE and OE are LOW for READ cycle.
3. ADDRESS must be valid prior to, or coincident with later of
CE transition LOW.
Document # SRAM129 REV D
Page 5 of 12