Displays
–
Interface Timing: Timing Parameters
Item
Power Supply
CLK
Frequency
Period
Display period
Pulse width
HSYNC
Back-porch
Front-porch
Hpw+Hbp
Hsync-CLK
Vsync-Hsync
Period
Display period
VSYNC
Pulse width
Back-porch
Front-porch
Vpw + Vbp
Horizontal scanning period
DENB
Horizontal display period
Vertical display period
Frame cycling period
R, G, B
CLK-DATA
DATA-CLK
Symbol
VCC
1/tc
tc
Hp
Hdp
Hpw
Hbp
Hfp
–
Hhc
Hvh
Vp
Vdp
Vpw
Vbp
Vfp
–
T1
T2
T3
T4
Dcd
Ddc
Min.
3.0
–
–
–
–
–
–
–
–
–
10
0
–
–
–
–
–
–
–
–
–
–
520
10
8
Typ.
3.3
25
40
32
800
640
96
46
18
142
–
0
16.8
525
480
2
33
10
35
800
640
480
525
–
–
AND050VL-LED-KIT
Max.
3.6
–
–
–
–
–
–
–
–
–
Tc-10
200
–
–
–
–
–
–
–
–
–
–
800
–
–
Unit
V
MHz
ns
us
tc
tc
tc
tc
tc
tc
ns
tc
ms
Hp
Hp
Hp
Hp
Hp
Hp
tc
tc
T1
T1
ns
ns
05/13/03
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
Tel: 408.523.8200 • Fax: 408.733.1287 • sales@purdyelectronics.com • www.purdyelectronics.com
6