June 2005
rev 0.2
Absolute Maximum Ratings
Parameter
Supply Voltage to Ground Potential
DC Input Voltage (Except REF)
DC Input Voltage (REF)
Storage Temperature
Junction Temperature
Static Discharge Voltage
(As per JEDEC STD 22- A114-B)
ASM2P2309NZ
Min
-0.5
-0.5
-0.5
-65
Max
7.0
V
DD
+ 0.5
0.7
+150
150
>2000
Unit
V
V
V
°C
°C
V
Note: These are stress ratings only and functional usage is not implied. Exposure to absolute maximum ratings for prolonged periods can affect device
reliability.
Operating Conditions
Parameter
V
DD
T
A
C
L
C
IN
BUF_IN, OUTPUT [1:9]
t
PU
Supply Voltage
(Ambient Operating Temperature), Commercial
(Ambient Operating Temperature), Industrial
Load Capacitance, Fout < 100 MHz
Load Capacitance,100 MHz < Fout < 133.33 MHz
Input Capacitance
Operating Frequency
Power-up time for all V
DD
's to reach minimum
specified voltage (power ramps must be monotonic)
Description
Min
3.0
0
–40
-
-
-
DC
0.05
Max
3.6
70
85
30
15
7
133.33
50
Unit
V
°C
°C
pF
pF
pF
MHz
mS
Nine Output 3.3V Buffer
Notice: The information in this document is subject to change without notice.
3 of 9