05113
30KPA30A
POWER TVS COMPONENT
APPliCAtions
• Relay Drives
• Motor (Start/Stop) Back EMF Protection
• Module Lightning Protection
• Secondary Lightning Protection for AC/DC
30KPA360CA
thru
iEC CoMPAtiBilitY
(EN61000-4)
• 61000-4-5 (Surge): 48A, 8/20µs - L3 (Line-Gnd), L4 (Line-Line) & L1 (Power)
FEAtUREs
• 30,000 Watts Peak Pulse Power per Line (tp=10/1000µs)
• Unidirectional & Bidirectional Configurations
• Easy Mounting to Printed Circuit Board
• Available in Multiple Voltage Types Ranging From: 30V to 360V
• tClamping (0V to V
BR
Min.) < 100ps, Theoretical for Unidirectional and < 5ns for Bidirectional
• RoHS Compliant
AXiAl lEAD
MECHAniCAl CHARACtERistiCs
• Molded Case
• Weight 5 grams (Approximate)
• Available in Lead-Free Pure-Tin Plating(Annealed)
• Solder Reflow Temperature:
Pure-Tin - Sn, 100: 260-270°C
• Consult Factory for Leaded Device Availability
• Flammability Rating UL 94V-0
• Marking: Logo, Part Number & Date Code
• Positive Terminal Marked with Band -
Unidirectional Only
30KPAxxx
wwyy
P
Pin ConFiGURAtions
Unidirectional
Bidirectional
1
www.protekdevices.com
05113.R21 11/10