TOP412/414  
V
IN  
V
IN  
0
DRAIN  
V
OUT  
0
0
I
OUT  
1
1
2
2
8
8
1
1
2
2
8
8
1
1
• • •  
• • •  
• • •  
• • •  
V
C(reset)  
V
C
0
0
45 mA  
I
C
3
4
1
1
2
PI-1119-110194  
Figure 6. Typical Waveforms for (1) Normal Operation, (2) Auto-restart, (3) Latching Shutdown, and (4) Power Down Reset.  
CONTROL pin. VC regulation changes from shunt mode to  
the hysteretic auto-restart mode described above. When the  
fault condition is removed, the power supply output becomes  
regulated, VC regulation returns to shunt mode, and normal  
operation of the power supply resumes.  
temperature exceeds the thermal shutdown temperature  
(typically 145 °C). Activating the power-up reset circuit by  
removing and restoring input power or momentarily pulling the  
CONTROL pin below the power-up reset threshold resets the  
latch and allows TOPSwitch to resume normal power supply  
operation. VC is regulated in hysteretic mode when the power  
supply is latched off.  
Latching Shutdown  
Theoutputovervoltageprotectionlatchisactivatedbyahigh-  
current pulse into the CONTROL pin. When set, the latch  
turns off the TOPSwitch output. Activating the power-up  
reset circuit by removing and restoring input power, or  
momentarily pulling the CONTROL pin below the power-up  
reset threshold resets the latch and allows TOPSwitch to  
resume normal power supply operation. VC is regulated in  
hysteretic mode when the power supply is latched off.  
High-voltage Bias Current Source  
ThiscurrentsourcebiasesTOPSwitch fromtheDRAINpinand  
charges the CONTROL pin external capacitance (CT) during  
start-up or hysteretic operation. Hysteretic operation occurs  
during auto-restart and latched shutdown. The current source  
is switched on and off with an effective duty cycle of  
approximately 35%. This duty cycle is determined by the ratio  
of CONTROL pin charge (IC) and discharge currents (ICD1 and  
ICD2). This current source is turned off during normal operation  
when the output MOSFET is switching.  
Over-Temperature Protection  
Temperature protection is provided by a precision analog  
circuit that turns the output MOSFET off when the junction  