LYT2002-2005
Conditions
SOURCE = 0 V; TJ = 0 to 100 °C
(Unless Otherwise Specified)
Parameter
Symbol
Min
Typ
Max
Units
Output (cont.)
VDS = 560 V
IDSS1
50
TJ = 125 °C, See Note C
OFF-State
Leakage
mA
V DS = 375 V
IDSS2
15
TJ = 50 °C
Breakdown
Voltage
BVDSS
TJ = 25 °C
725
50
V
V
DRAIN Pin
Supply Voltage
tON × IFB = 1.4 mAms
fOSC = 12 kHz
VFB = 0
Auto-Restart
ON-Time
tAR-ON
100
ms
s
See Notes A, E
Auto-Restart
OFF-Time
tAR-OFF
See Note E
0.32
Open-Loop
FEEDBACK Pin
Current Threshold
IOL
See Note E
See Note E
-45
1.4
mA
Open-Loop
ON-Time
ms
NOTES:
A. Auto-restart on-time is a function of switching frequency programmed by tonx IFB and minimum frequency in CC mode.
B. The current limit threshold is compensated to cancel the effect of current limit delay. As a result the output current stays constant across
the input line range.
C. IDSS1 is the worst-case off-state leakage specification at 80% of BVDSS and maximum operating junction temperature. IDSS2 is a typical
specification under worst-case application conditions (rectified 265 VAC) for no-load consumption calculations.
D. When the duty cycle exceeds DCMAX the LYTSwitch-2 operates in on-time extension mode.
E. This parameter is derived from characterization.