LinkSwitch-HP
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
(Unless Otherwise Specified)
Parameter
Symbol
Min
Typ
Max
Units
Output
TJ = +25 °C
6.9
10.5
4.6
7.0
3.5
5.4
2.3
3.6
1.8
2.7
7.97
12.08
5.30
8.09
4.03
6.21
2.65
4.14
2.07
3.11
LNK6xx3
ID = 100 mA
TJ = +100 °C
TJ = +25 °C
LNK6xx4
ID = 150 mA
TJ = +100 °C
TJ = +25 °C
LNK6xx5
ID = 200 mA
ON-State Resistance
RDS(ON)
W
TJ = +100 °C
TJ = +25 °C
LNK6xx6
ID = 300 mA
TJ = +100 °C
TJ = +25 °C
LNK6xx7
ID = 400 mA
TJ = +100 °C
VDS = 560 V, TJ = 125 °C
470
10
OFF-State Drain
Leakage Current
VPD
Floating
=
IDSS
mA
VDS = 325 V, TJ = 100 °C
LNK677x, VPD = Floating,
TJ = +25 °C
725
650
50
Breakdown Voltage
BVDSS
V
LNK666x/LNK676x, VPD = Floating,
TJ = +25 °C
DRAIN Supply Voltage
V
Rise Time
Fall Time
tR
100
50
Measured in a typical flyback
Converter application
ns
TF
NOTES:
A. Parameter not tested over specified temperature range. Guaranteed by design and characterization.
B. Average device switching frequency below 1 kHz.
16
Rev. C 03/14
www.powerint.com