LNK623-626
Conditions
SOURCE = 0 V; TJ = -40 to ±21 °C
(Unless Otherwise Specified)
Parameter
Symbol
Min
Typ
Max
Units
Output
24
36
24
36
±6
24
9.6
±4
28
42
28
42
±9
28
±±
±7
TJ = 21 °C
LNK623
ID = 10 mA
TJ = ±00 °C
TJ = 21 °C
LNK624
ID = 10 mA
TJ = ±00 °C
ON-State
Resistance
RDS(ON)
Ω
TJ = 21 °C
LNK621
ID = 62 mA
TJ = ±00 °C
TJ = 21 °C
LNK626
ID = 82 mA
TJ = ±00 °C
VDS = 160 V (See Figure 20)
IDSS±
10
TJ = ±21 °C (See Note ±)
OFF-State
Leakage
μA
VDS = 371 V (See Figure 20)
IDSS2
±1
TJ = 10 °C
Breakdown
Voltage
TJ = 21 °C
(See Figure 20)
BVDSS
700
10
V
V
DRAIN Supply
Voltage
Auto-Restart
ON-Time
VFB = 0
(See Note 3)
tAR-ON
tAR-OFF
IOL
200
2.1
ms
s
Auto-Restart
OFF-Time
Open-Loop FB Pin
Current Threshold
(See Note 3)
(See Note 3)
-±20
90
μA
μs
Open-Loop
ON-Time
NOTES:
±. IDSS± is the worst case OFF state leakage specification at 805 of BVDSS and maximum operating junction temperature. IDSS2 is a
typical specification under worst case application conditions (rectified 261 VAC) for no-load consumption calculations.
2. When the duty cycle exceeds DCMAX the LinkSwitch-CV operates in on-time extension mode.
3. This parameter is derived from characterization.
13
www.powerint.com
Rev. E 09/09