LNK603-606/613-616  
Conditions  
(Unless OtherwiJse Specified)  
SOURCE = 0 V; T = 0 to 100 °C  
Parameter  
Symbol  
Min  
Typ  
Max  
Units  
Output  
24  
36  
24  
36  
16  
24  
9.6  
14  
28  
42  
28  
42  
19  
28  
11  
17  
TJ = 25 °C  
LNK6X3  
ID = 50 mA  
TJ = 100 °C  
TJ = 25 °C  
LNK6X4  
ID = 50 mA  
TJ = 100 °C  
ON-State  
Resistance  
RDS(ON)  
W
TJ = 25 °C  
LNK6X5  
ID = 62 mA  
TJ = 100 °C  
TJ = 25 °C  
LNK6X6  
ID = 82 mA  
TJ = 100 °C  
VDS = 560 V See Figure 20  
IDSS1  
50  
TJ = 125 °C See Note 3  
OFF-State  
Leakage  
mA  
VDS = 375 V See Figure 20  
IDSS2  
15  
TJ = 50 °C  
Breakdown  
Voltage  
TJ = 25 °C  
See Figure 20  
BVDSS  
700  
50  
V
V
DRAIN Supply  
Voltage  
tON × IFB = 2 mA-ms, fOSC = 12 kHz  
VFB = 0  
Auto-Restart  
ON-Time  
tAR-ON  
tAR-OFF  
IOL  
450  
1.2  
ms  
s
See Notes 1, 5  
Auto-Restart  
OFF-Time  
2
Open-Loop  
FEEDBACK Pin  
Current Threshold  
See Note 5  
See Note 5  
-120  
90  
mA  
ms  
Open-Loop  
ON-Time  
NOTES:  
1. Auto-restart ON-time is a function of switching frequency programmed by tonx IFB and minimum frequency in CC mode.  
2. The current limit threshold is compensated to cancel the effect of current limit delay. As a result the output current stays constant  
across the input line range.  
3. IDSS1 is the worst case OFF state leakage specification at 80% of BVDSS and maximum operating junction temperature. IDSS2 is a  
typical specification under worst case application conditions (rectified 265 VAC) for no-load consumption calculations.  
4. When the duty-cycle exceeds DCMAX the LinkSwitch-II operates in on-time extension mode.  
5. This parameter is derived from characterization.  
6. Mechanical stress induced during the assembly may cause shift in this parameter. This shift has no impact on the ability of  
LinkSwitch-II to meet 10% in mass production given the design follows recommendation in AN-44 and good manufacturing practice  
7. The switching frequency is programmable between 60 kHz and 85 kHz.  
10  