欢迎访问ic37.com |
会员登录 免费注册
发布采购

LNK4115D-TL 参数 Datasheet PDF下载

LNK4115D-TL图片预览
型号: LNK4115D-TL
PDF下载: 下载PDF文件 查看货源
内容描述: [IC OFF-LINE CNTRLR 18W 8SO]
分类和应用:
文件页数/大小: 22 页 / 1423 K
品牌: POWERINT [ Power Integrations ]
 浏览型号LNK4115D-TL的Datasheet PDF文件第11页浏览型号LNK4115D-TL的Datasheet PDF文件第12页浏览型号LNK4115D-TL的Datasheet PDF文件第13页浏览型号LNK4115D-TL的Datasheet PDF文件第14页浏览型号LNK4115D-TL的Datasheet PDF文件第16页浏览型号LNK4115D-TL的Datasheet PDF文件第17页浏览型号LNK4115D-TL的Datasheet PDF文件第18页浏览型号LNK4115D-TL的Datasheet PDF文件第19页  
LinkSwitch-4  
Conditions  
TJ = -25 to 125 °C  
(Unless Otherwise Specified)  
Parameter  
Symbol  
Min  
Typ  
Max  
Units  
FEEDBACK Pin (Cont.)  
Feedback Current Low  
Mains Threshold  
IFBHT(LO)  
-0.495  
-1.05  
-0.412  
-0.31  
-0.75  
mA  
mA  
Feedback Current  
Start Mains Threshold  
IFBHT(START)  
-0.9  
1.5  
Fixed for LNK40x2S and LNK43x2S  
RCS2 = 100 Ω  
1.5  
2.2  
VOUT  
RCS2 = 270 Ω  
RCS2 = 470 Ω  
RCS2 = 1000 Ω  
RCS2 = 100 Ω  
RCS2 = 270 Ω  
RCS2 = 470 Ω  
RCS2 = 1000 Ω  
0.7  
VOUT(CV)  
2.5  
Feedback  
Blanking Time  
tFB(BL)  
ms  
2.5  
0.75  
1.1  
VOUT  
>0.7  
VOUT(CV)  
1.25  
1.25  
600  
700  
1700  
LNK40x3S / LNK40x3D  
LNK43xxS / LNK43xxD  
LNK4xx5D  
Start-up Cycle Count  
NSTARTUP  
Transient Detect  
Pulse Duration  
LNK40x3S / LNK40x3D / LNK40x4D / LNK4114D /  
LNK4214D / LNK4115D / LNK4215D  
tTD  
100  
60  
ns  
LNK40x3S / LNK40x3D / LNK40x4D / LNK4114D /  
LNK4214D / LNK4115D / LNK4215D / LNK4323S  
/ LNK4323D  
Transient Detect  
Threshold  
VTD  
mV  
CURRENT SENSE Pin  
LNK40x2S / LNK43x2S  
LNK40x3S  
-88  
-56  
RCS2= 100 Ω  
LNK40x3D  
LNK40x4D  
Outside Primary  
LNK4114D  
Primary Current Sense  
Input Minimum  
Threshold  
R
CS2= 270 Ω  
CS2= 470 Ω  
-73  
-94  
Current Sense  
Blanking Time  
tCS(B)  
LNK4214D  
LNK4115D  
LNK4215D  
VCS(MIN)  
mV  
R
LNK4323S  
LNK4323D  
(Set by External  
RCS2= 1000 Ω  
-127  
Resistor RCS2  
)
Primary Current Sense  
Input Maximum  
Threshold  
Outside Primary Current  
Sense Blanking Time  
tCS(B)  
VCS(OCP)  
VCS(MAX)  
Over-Current Protect  
Normal Regulation  
-350  
-380  
-340  
-360  
-330  
-340  
mV  
mV  
Primary Current Sense  
Turn-Off Response  
Time  
Outside Primary Current Sense  
tCS(OFF)  
120  
ns  
Blanking Time tCS(B)  
TJ = 25 °C  
Except LNK4115D, LNK4214D, LNK4215D  
-62  
-60.8  
-59.6  
Primary Current Sense  
Threshold for CC  
Operation  
LNK4115D Only  
LNK4214D Only  
LNK4215D Only  
-68  
-105  
-119  
VCS(CC)  
mV  
15  
Rev. F 05/18  
www.power.com  
 复制成功!