InnoSwitch3-EP
Conditions
SOURCE = 0 V
TJ = -40 °C to 125 °C
Parameter
Symbol
Min
Typ
Max
Units
(Unless Otherwise Specified)
Circuit Protection (cont.)
BYPASS Pin Latching
Shutdown Threshold
Current
ISD
TJ = 25 °C
TJ = 25 °C
6.0
75
8.9
11.3
mA
Auto-Restart On-Time
tAR
82
89
ms
sec
sec
sec
Auto-Restart Trigger
Skip Time
TJ = 25 °C
See Note A
tAR(SK)
1.3
Auto-Restart Off-Time
tAR(OFF)
tAR(OFF)SH
TJ = 25 °C
TJ = 25 °C
1.7
2.11
Short Auto-Restart
Off-Time
0.17
0.20
0.23
Output
TJ = 25 °C
6.30
9.77
4.42
6.85
3.22
4.99
1.95
3.02
1.34
2.08
1.20
1.86
7.25
11.24
5.08
7.88
3.70
5.74
2.24
3.47
1.54
2.39
1.38
2.14
INN3672C
ID = ILIMIT+1
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
INN3673C
ID = ILIMIT+1
INN3674C
ID = ILIMIT+1
Ω
ON-State Resistance
RDS(ON)
INN3675C
ID = ILIMIT+1
INN3676C
ID = ILIMIT+1
INN3677C
ID = ILIMIT+1
VBPP = VBPP + 0.1 V
IDSS1
VDS = 150 V
TJ = 25 °C
15
mA
mA
OFF-State Drain
Leakage Current
VBPP = VBPP + 0.1 V
VDS = 325 V
IDSS2
200
TJ = 25 °C
22
Rev. D 08/18
www.power.com