22-Jun-2006
EP-93 – 30 V, 1.07 A, 2.7 A (peak), Universal Input Supply
11.6 AC Line Disturbance
All measurements taken at 32 W output load.
Figure 20 – Half-Cycle Dropout, 90 VAC, 60 Hz.
Top Trace: Output Voltage, 20 V/div.
Figure 21 – Half-Cycle Dropout, 120 VAC, 60 Hz.
Top Trace: Output Voltage, 20 V/div.
Middle Trace: Output Current, 2 A/div.
Middle Trace: Output Current, 2 A/div.
Bottom Trace: AC Input Voltage, 100 V, 20 ms/div.
Bottom Trace: AC Input Voltage, 100 V, 20 ms/div.
Figure 22 – Half-Cycle Dropout, 216 VAC, 50 Hz.
Top Trace: Output Voltage, 20 V/div.
Figure 23 – Half-Cycle Dropout, 240 VAC, 50 Hz.
Top Trace: Output Voltage, 20 V/div.
Middle Trace: Output Current, 2 A/div.
Middle Trace: Output Current, 2 A/div.
Bottom Trace: AC Input Voltage, 200 V, 20 ms/div.
Bottom Trace: AC Input Voltage, 200 V, 20 ms/div.
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 27 of 40