07-May-2004
EPR-54 – LinkSwitch 2.75 W Low Cost Charger / Adapter
7 Transformer Specification
Note: To correctly center the output voltage over a junction temperature of 25 °C to 65 °C
(approx ambient 0 °C to 40 °C), the design software and design methodology may
produce a slightly different transformer design than the one shown here.
7.1 Electrical Diagram
3
Shield
WDG #1
1
1
7
Primary
WDG #2
WDG #4
Secondary
WDG #3
100T #32 AWG
8T #30 T.I.W
6
2
4
Shield & Bias
26T #31 AWG
5
Figure 5 – Transformer Electrical Diagram.
7.2 Electrical Specifications
Electrical Strength
Primary Inductance
Resonant Frequency
Primary Leakage Inductance
1 second, 60 Hz, from Pins 1-5 to Pins 6-10
3000 VAC
Pins 1-2, all other windings open, measured at
100 kHz, 0.4 VRMS
2.52 mH, +/-10%
400 kHz (Min.)
80 µH (Max.)
Pins 1-2, all other windings open
Pins 1-2, with Pins 6-7 shorted, measured at
100 kHz, 0.4 VRMS
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 11 of 40