欢迎访问ic37.com |
会员登录 免费注册
发布采购

EPR-000008 参数 Datasheet PDF下载

EPR-000008图片预览
型号: EPR-000008
PDF下载: 下载PDF文件 查看货源
内容描述: 工程原型报告1.2 W ,通用输入,非隔离, TNY254 ( EP8 ) [Engineering Prototype Report 1.2 W, Universal Input, Non-isolated, TNY254 (EP8)]
分类和应用:
文件页数/大小: 20 页 / 693 K
品牌: POWERINT [ Power Integrations ]
 浏览型号EPR-000008的Datasheet PDF文件第12页浏览型号EPR-000008的Datasheet PDF文件第13页浏览型号EPR-000008的Datasheet PDF文件第14页浏览型号EPR-000008的Datasheet PDF文件第15页浏览型号EPR-000008的Datasheet PDF文件第16页浏览型号EPR-000008的Datasheet PDF文件第18页浏览型号EPR-000008的Datasheet PDF文件第19页浏览型号EPR-000008的Datasheet PDF文件第20页  
23-April-2001  
EPR-000008 – 1.2 W Universal Input Non-Isolated TNY254  
8.6  
Surge Voltage Immunity (2 kV and 6 kV, 1.2/50 s per IEC1000-4-5)  
Two series of surge tests were performed:  
Configuration “1” (2 kV), Fig. 8.6.1 and configuration “2” (6 kV), Fig. 8.6.2 passed 20  
surges each at 45 seconds apart; 10 surges with positive (Fig. 8.6.3) and 10 with  
negative polarity (Fig. 8.6.4), all at high input line and full load. The 45 seconds delay  
between surges allows the energy rated components (R1, R2 and RV1) to cool down.  
High input line is the worst case condition as the input capacitor (C1) reaches highest  
voltage therefore minimizing margin for TinySwitch breakdown voltage.  
R2 limits the charging current during a +voltage surge such that C1 peak voltage does  
not exceed the TNY254 breakdown voltage.  
R1 limits the maximum surge current to approximately 50 A, the value at which the  
clamping voltage of the varistor is characterized (<700 V). The 6 kV, 1.2/50 s pulse at  
700 V clipping level is approximately 100 s (see Fig. 8.7.2). From the graph in Fig. 8.6.5,  
it can be inferred that the unit will survive 10 k surges of -6 kV (more of +6 kV as C1 can  
divert ~0.3 J).  
Reducing the value of R1 would reduce the total number of 6 kV pulses the unit can  
survive.  
J1-1  
J1-1  
L
L
C1  
C1  
+
+
85-265 VAC, 50/60 Hz  
RV1  
6.8 F  
85-265 VAC, 50/60 Hz  
6.8 F  
400 V  
400 V  
D1  
D3  
D1  
R2  
J1-3  
R1  
R2  
180 ,
 
3 W, fusible  
J1-3  
N
N
1N4007  
1N4007 180 , 3 W, fusible  
100 ,
 
surge  
1N4007  
Figure 8.6.1 - Configuration “1”, 2 kV.  
Figure 8.6.2 - Configuration “2”, 6 kV.  
Power Integrations, Inc.  
Tel: +1 408 414 9200 Fax: +1 408 414 9201  
www.powerint.com  
Page 17 of 20  