DPA422-426
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
See Figure 33
Parameter
Symbol
Min
Typ
Max
Units
(Unless Otherwise Specified)
Circuit Protection (cont.)
Initial Current Limit
0.9 ×
ILIMIT(MIN)
IINIT
VD = 35 V
A
Leading Edge
Blanking Time
tLEB
TIL(D)
TJ(SD)
TJ = 25 °C
100
145
ns
ns
°C
Current Limit Delay
IC = (IC(SKIP) + IB)/2
100
137
Thermal Shutdown
Temperature
130
1.5
Thermal Shutdown
Hysteresis
TJ(SD)HYST
VC(RESET)
27
°C
V
Power-Up Reset
Threshold Voltage
2.75
4
Output
TJ = 25 °C
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
TJ = 25 °C
TJ = 100 °C
DPA422
2.60
4.00
1.30
2.00
0.65
1.00
0.33
0.50
0.24
0.37
3.00
4.60
1.50
2.30
0.75
1.15
0.38
0.58
0.28
0.43
33
DPA422
ID = 150 mA
DPA423
ID = 300 mA
DPA424
ID = 600 mA
ON-State Resistance
RDS(ON)
W
DPA425
ID = 1.25 A
DPA426
ID = 1.75 A
VX, VL = Floating;
VD = 150 V;
TJ = 125 °C;
DPA423
65
OFF-State Drain
Leakage Current
IDSS
DPA424
130
260
360
µA
DPA425
IC = (IC(SKIP) + IB)/2
DPA426
VX, VL = Floating; TJ = 25 °C;
Breakdown Voltage
BVDSS
220
V
IC = (IC(SKIP) + IB)/2; See Note C
Measured in a Typical Application
Measured in a Typical Application
Rise Time
Fall Time
tR
tF
10
10
ns
ns
24
Rev. T 12/12
www.powerint.com