欢迎访问ic37.com |
会员登录 免费注册
发布采购

DER-94 参数 Datasheet PDF下载

DER-94图片预览
型号: DER-94
PDF下载: 下载PDF文件 查看货源
内容描述: 46 W电源使用TOP246Y [46 W Power Supply using TOP246Y]
分类和应用:
文件页数/大小: 34 页 / 596 K
品牌: POWERINT [ Power Integrations ]
 浏览型号DER-94的Datasheet PDF文件第15页浏览型号DER-94的Datasheet PDF文件第16页浏览型号DER-94的Datasheet PDF文件第17页浏览型号DER-94的Datasheet PDF文件第18页浏览型号DER-94的Datasheet PDF文件第20页浏览型号DER-94的Datasheet PDF文件第21页浏览型号DER-94的Datasheet PDF文件第22页浏览型号DER-94的Datasheet PDF文件第23页  
DER-94  
LCD Monitor Internal Supply  
September 12, 2005  
VOLTAGE STRESS PARAMETERS  
VDRAIN  
584  
584 Volts  
Maximum Drain Voltage  
Estimate (Includes Effect of  
Leakage Inductance)  
PIVS  
PIVB  
28  
65  
28 Volts  
65 Volts  
Output Rectifier Maximum  
Peak Inverse Voltage  
Bias Rectifier Maximum  
Peak Inverse Voltage  
TRANSFORMER SECONDARY DESIGN PARAMETERS (MULTIPLE OUTPUTS)  
1st output  
VO1  
IO1  
PO1  
VD1  
5.0  
2.000  
Volts  
Amps  
10.00 Watts  
Volts  
Output Voltage  
Output DC Current  
Output Power  
Output Diode Forward  
Voltage Drop  
10.00  
0.5  
NS1  
3.00  
3.039  
2.29  
28  
3.00  
Output Winding Number of  
Turns  
Output Winding RMS  
Current  
Output Capacitor RMS  
Ripple Current  
Output Rectifier Maximum  
Peak Inverse Voltage  
ISRMS1  
IRIPPLE1  
PIVS1  
3.039 Amps  
2.29 Amps  
28 Volts  
CMS1  
608  
22  
608 Cmils  
22 AWG  
Output Winding Bare  
Conductor minimum circular  
mils  
Wire Gauge (Rounded up to  
next larger standard AWG  
value)  
AWGS1  
DIAS1  
ODS1  
0.65  
3.73  
0.65 mm  
3.73 mm  
Minimum Bare Conductor  
Diameter  
Maximum Outside Diameter  
for Triple Insulated Wire  
2nd output  
VO2  
IO2  
PO2  
VD2  
12.0  
3.000  
Volts  
Amps  
36.00 Watts  
Volts  
Output Voltage  
Output DC Current  
Output Power  
Output Diode Forward  
Voltage Drop  
36.00  
1.0  
NS2  
7.09  
4.558  
3.43  
66  
7.09  
Output Winding Number of  
Turns  
Output Winding RMS  
Current  
Output Capacitor RMS  
Ripple Current  
Output Rectifier Maximum  
Peak Inverse Voltage  
ISRMS2  
IRIPPLE2  
PIVS2  
4.558 Amps  
3.43 Amps  
66 Volts  
CMS2  
912  
20  
912 Cmils  
20 AWG  
Output Winding Bare  
Conductor minimum circular  
mils  
Wire Gauge (Rounded up to  
next larger standard AWG  
value)  
AWGS2  
DIAS2  
ODS2  
0.81  
1.58  
0.81 mm  
1.58 mm  
Minimum Bare Conductor  
Diameter  
Maximum Outside Diameter  
for Triple Insulated Wire  
Power Integrations  
Tel: +1 408 414 9200 Fax: +1 408 414 9201  
www.powerint.com  
Page 19 of 34  