DER-94
LCD Monitor Internal Supply
September 12, 2005
VOLTAGE STRESS PARAMETERS
VDRAIN
584
584 Volts
Maximum Drain Voltage
Estimate (Includes Effect of
Leakage Inductance)
PIVS
PIVB
28
65
28 Volts
65 Volts
Output Rectifier Maximum
Peak Inverse Voltage
Bias Rectifier Maximum
Peak Inverse Voltage
TRANSFORMER SECONDARY DESIGN PARAMETERS (MULTIPLE OUTPUTS)
1st output
VO1
IO1
PO1
VD1
5.0
2.000
Volts
Amps
10.00 Watts
Volts
Output Voltage
Output DC Current
Output Power
Output Diode Forward
Voltage Drop
10.00
0.5
NS1
3.00
3.039
2.29
28
3.00
Output Winding Number of
Turns
Output Winding RMS
Current
Output Capacitor RMS
Ripple Current
Output Rectifier Maximum
Peak Inverse Voltage
ISRMS1
IRIPPLE1
PIVS1
3.039 Amps
2.29 Amps
28 Volts
CMS1
608
22
608 Cmils
22 AWG
Output Winding Bare
Conductor minimum circular
mils
Wire Gauge (Rounded up to
next larger standard AWG
value)
AWGS1
DIAS1
ODS1
0.65
3.73
0.65 mm
3.73 mm
Minimum Bare Conductor
Diameter
Maximum Outside Diameter
for Triple Insulated Wire
2nd output
VO2
IO2
PO2
VD2
12.0
3.000
Volts
Amps
36.00 Watts
Volts
Output Voltage
Output DC Current
Output Power
Output Diode Forward
Voltage Drop
36.00
1.0
NS2
7.09
4.558
3.43
66
7.09
Output Winding Number of
Turns
Output Winding RMS
Current
Output Capacitor RMS
Ripple Current
Output Rectifier Maximum
Peak Inverse Voltage
ISRMS2
IRIPPLE2
PIVS2
4.558 Amps
3.43 Amps
66 Volts
CMS2
912
20
912 Cmils
20 AWG
Output Winding Bare
Conductor minimum circular
mils
Wire Gauge (Rounded up to
next larger standard AWG
value)
AWGS2
DIAS2
ODS2
0.81
1.58
0.81 mm
1.58 mm
Minimum Bare Conductor
Diameter
Maximum Outside Diameter
for Triple Insulated Wire
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 19 of 34