with respect to the load transient, contributions to the output ripple from these sources
will average out, leaving the contribution only from the load step response.
Figure 17 – Transient Response, 90 VAC, 60-100-
60% Load Step.
Figure 18 – Transient Response, 90 VAC, 60-100-
60% Load Step
Top: Load Current, 1 A/div.
Bottom: 3V3 Output Voltage
10 mV, 10 ms / div.
Upper: Load Current, 1 A/ div.
Bottom: 5V Output Voltage
10 mV, 10 ms / div.
Figure 19 – Transient Response, 90 VAC, 50-100-
50% Load Step.
Figure 20 – Transient Response, 90 VAC, 50-100-
50% Load Step
Top: Load Current, 0.5 A/div.
Bottom: 18V Output Voltage
10 mV, 10 ms / div.
Upper: Load Current, 0.5 A/ div.
Bottom: 23V Output Voltage
10 mV, 10 ms / div.