DER-46
6 W peak, Multiple output PSU for DVB-T
April 20, 2005
9.2 Worst Case Cross Regulation
The test was done at room temperature at minimum and maximum input voltage.
Voltage input @195Vac
Load (A)
Output (V)
3.3V
0.3
0
2.5V
0.55
0.55
0.22
0.20
0.55
0.55
0.70
0.70
5V
0.1
12V
0.13
0.13
0.13
0.15
0.1
33V
3.3V
3.34
3.35
3.37
3.36
3.33
3.33
3.33
3.34
2.5V
2.52
2.53
2.58
2.57
2.51
2.5
5V
12V
33V
32.29
31.98
31.27
31.77
32.5
2mA
4.98
4.91
4.77
4.77
5.19
5.18
5.18
4.91
12.17
11.95
11.53
11.73
12.43
12.42
12.42
12.16
0.1
2
2
2
2
2
2
2
0
0.1
0.2
0.3
0.3
0.4
0.4
0.15
0.03
0.01
0.01
0.15
0.08
0.08
0.15
32.6
2.50
2.52
32.6
32.4
Voltage input @265Vac
Load (A)
Output (V)
3.3V
0.3
0
2.5V
0.55
0.55
0.22
0.20
0.55
0.55
0.70
0.70
5V
0.1
12V
0.13
0.13
0.13
0.15
0.1
33V
3.3V
3.34
3.35
3.37
3.36
3.33
3.33
3.33
3.34
2.5V
2.52
2.53
2.58
2.57
2.51
2.51
2.50
2.52
5V
5.0
12V
12.19
11.93
11.53
11.74
12.38
12.47
12.46
12.20
33V
32.44
32.09
31.39
31.86
32.6
2mA
0.1
2
2
2
2
2
2
2
4.92
4.78
4.78
5.20
5.21
5.20
4.93
0
0.1
0.2
0.3
0.3
0.4
0.4
0.15
0.03
0.01
0.01
0.15
0.08
0.08
0.15
32.6
32.8
32.5
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 14 of 22