DER-37
16W Adapter using TOP245P
April 27, 2004
14.1.2 Output floating
Figure 33 – NEUTRAL Conducted EMI, Maximum Steady State Load, 230 VAC, 60 Hz, and EN55022 B
Limits. Without the LISN’s PE connection to secondary ground.
Figure 34 – LINE Conducted EMI, Maximum Steady State Load, 230 VAC, 60 Hz, and EN55022 B Limits.
Without the LISN’s PE connection to secondary ground.
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
Page 28 of 32