 浏览型号ZM7308G-65502-T2的Datasheet PDF文件第22页浏览型号ZM7308G-65502-T2的Datasheet PDF文件第23页浏览型号ZM7308G-65502-T2的Datasheet PDF文件第24页浏览型号ZM7308G-65502-T2的Datasheet PDF文件第25页浏览型号ZM7308G-65502-T2的Datasheet PDF文件第27页浏览型号ZM7308G-65502-T2的Datasheet PDF文件第28页浏览型号ZM7308G-65502-T2的Datasheet PDF文件第29页浏览型号ZM7308G-65502-T2的Datasheet PDF文件第30页  
ZM7300G Series Digital Power Manager  
Data Sheet  
The ACFAIL_N and RES_N inputs should be controlled with open collector devices. The propagation  
delay between the external device pulling the input low and the DPM pulling down OK lines and  
triggering the turn-off process is approximately 1ms.  
10.6.2 Front End Enable  
The FE_EN pin is dedicated to the control of a DC-DC Front End. The Front End is typically used to  
convert the 48V into the intermediate bus voltage (IBV). If the DPM is powered from an auxiliary  
source, not from the IBV, it can control the DC-DC Front End.  
When FE_EN is internally pulled up to 3.3V, the Front End is enabled. The FE_EN output can provide  
up to 5mA of current. When the FE_EN goes low, the Front End is disabled. The Front End can be  
enabled and disabled via the GUI IBS Monitoring Window or directly via the I2C bus using specific  
commands.  
The FE_EN pin should not be directly connected to the Enable pin of the DC-DC Front End. Typically,  
the Enable pin is referenced to the primary side of the Front End that is isolated from the low voltage  
secondary side. In addition, the Enable pin can be pulled up internally to a voltage potentially damaging  
to the DPM FE_EN output. The best method is to interface the DPM with the Front End through an  
optocoupler as shown in Figure 20. This configuration provides interface for negative logic front ends.  
Front End  
DPM  
FE_EN  
R
Enable  
Q
3.3k  
-VIN  
GND  
Figure 20. Interface Between DPM and DC-DC Front End  
10.6.3 Crowbar  
When the crowbar protection is enabled, the CB pin is internally pulled up to 3.3V for 1ms. It is capable  
of supplying 5mA to turn on a crowbar circuit.  
10.6.4 HRES_N  
The HRES_N is an active low digital input. When it is pulled low, the DPM will perform full hardware  
reset including processor, memory, and communication interface. The POL converters and auxiliary  
devices will be turned off although sequencing and tracking during the turn-off are not guaranteed.  
Communication with a host processor or GUI (if established) will be lost. When the input is released,  
the DPM will first program all POL converters and then turn them on, if the Auto Turn-On is enabled.  
Unlike all other I/O pins on the ZM7300 DPM, the HRES_N does not have an internal ESD protection  
diode connected to VDD. Therefore, it is necessary to add the diode externally as shown in Figure 3.  
ZD-00896 Rev. 5.1, 13-Jul-10  
www.power-one.com  
Page 26 of 33  