FNP1500/1800 Front-Ends  
& FNR-3 Power Shelf Data Sheet  
Fulcrum:  
The handle has been designed to allow easy plug-in and -out in a rack system. The handle (lever) fits into a counter piece  
(fulcrum) which is fixed to the bottom of the rack. During the plug, the fulcrum holds the unit down and guides it towards the  
output connector. The Power-One part number of the fulcrum and its associated mounting accessories is: HZZ01223.  
Individual fulcrum sets can be also ordered: Power-One part no.: HZZ01223.  
Note: Each HZZ01223 set contain 2 fulcrums, 2 supports, and mounting accessories.  
I2C to USB Interface HZZ02002G:  
I2C <to>USB  
Interface  
I2C Management Software: All FNP front-ends can be controlled via Power-One's GUI-driven I2C Management  
software and an I2C-to-USB interface (P/N HZZ02002G). An I2C Programming Manual describes the complete  
range of parameters that can be programmed to the FNP1500/1800 front-ends. This manual is available by  
searching on "FNP1500" at www.power-one.com.  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical  
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent  
of the respective divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  