欢迎访问ic37.com |
会员登录 免费注册
发布采购

DSP1N5S15 参数 Datasheet PDF下载

DSP1N5S15图片预览
型号: DSP1N5S15
PDF下载: 下载PDF文件 查看货源
内容描述: 单路输出 [SINGLE OUTPUT]
分类和应用: 输出元件
文件页数/大小: 3 页 / 227 K
品牌: POWER-ONE [ POWER-ONE ]
 浏览型号DSP1N5S15的Datasheet PDF文件第1页浏览型号DSP1N5S15的Datasheet PDF文件第3页  
DSP1 SERIES – SINGLE OUPUT
Output Parameters (
1)
Model
Output Voltage
Output Voltage Accuracy (3)
Output Voltage, No Load
Rated Load Range
Load Regulation (4)
75% - 20% Load
75% - 100% Load
Line Regulation (5)
Noise, Peak - Peak (2)
Temperature Coefficient
MIN
TYP
MAX
TYP
MIN
MAX
TYP
TYP
TYP
TYP
TYP
DSP1N5S5
5
4.75
5.00
5.25
7
0
150
DSP1N5S7
7
6.65
7.00
7.35
10
0
140
DSP1N5S12
12
11.40
12.00
12.60
16
0
80
+8
-5
1.6
70
40 0
Momentary
DSP1N5S14
14
13.30
14.00
14.70
19
0
70
DSP1N5S15
15
14.25
15.00
15.75
21
0
65
DSP1N5S17
17
16.15
17.00
17.85
24
0
60
Units
VDC
VDC
VDC
mA
%
%
mV
PP
ppm/
°C
Short Circuit Protection to Common (6)
NOTES
(1)
(2)
(3)
(4)
(5)
(6)
All parameters measured at Tc=25°C, nominal input voltage and full rated load unless otherwise noted.
Measurement bandwidth is 20 MHz. Input Reflected Ripple and output noise are measured with an exter-
nal 10µF/25V tantalum capacitor connected across the input and output pins.
Output Voltage Accuracy measured at 75% of maximum Rated Load.
Load Regulations measured relative to 75% of maximum Rated Load Current.
Line Regulation is for a 1.0% change in input Voltage.
Use input fuse for protection. See Applying the input.
DSP1 SERIES APPLICATION NOTES:
External Capacitance Requirements
Output filtering is required for operation. A minimum of
10 F is specified for optimal performance. Output capaci-
tance may be increased for additional filtering, not to
exceed 400 F. To meet the reflected ripple requirements of
the converter, an input impedance of less than 0.5 Ohms
from DC to 350KHz is required. If a capacitive input source
is farther than 2” from the converter, it is recommended to
use a 10 F, 25V solid tantalum capacitor.
Regulation
This converter uses a semi-regulated design. The output will
vary as the load is changed, with output decreasing with
increasing load. See Output Voltage vs. Output Load curves.
Additionally, output voltage will change in proportion to a
change in input voltage. The typical output voltage will
change 1.2% for each 1% change in input voltage.
Negative Outputs
A negative output voltage may be obtained by connecting
the +OUT to circuit ground and connecting -OUT as the
negative output.
2