P Series
120...195Watt DC-DC Converters
Control
Output voltage adjustment
Inhibit on input side
Status indication
output 1, 4
TTL input, output(s) disabled if open circuit
LEDs: In OK, Out OK
60/80...110% Uo nom
Output good signal (Out OK)
isolated open collector signal
Safety
Approvals
EN 60950, UL 1950, CSA C22.2 No. 950
Class of equipment
Protection degree
Electric strength test voltage
class I
IP 40
1.5 kV AC
I/case, O/case, Out OK/case
I/O, Out OK/I, Out OK/O
O/O
4242 V DC / 3 kV AC
500 V DC
EMC
Electrostatic discharge
Electromagnetic field
Electr. fast transients/bursts
Surge
Conducted disturbances
Electromagnetic emissions
IEC/EN 61000-4-2, level 4 (8/15 kV)
IEC/EN 61000-4-3, level 3 (10 V/m)
IEC/EN 61000-4-4, output/input, level 3/4 (2/4 kV)
IEC/EN 61000-4-5, input, level 2/3 (1/2 kV)
IEC/EN 61000-4-6, level 2/3 (3/10 V)
CISPR 22/EN 55022, conducted
criterion B
criterion A
criterion B
criterion B
criterion A
class B
Environmental
Operating ambient temperature Ui nom, Po nom, convection cooled
Operating case temperature TC Ui nom, Po nom/Po max
–25...71°C
–25...95°C
–40...100°C
56 days
0.35 mm/5 gn
50 gn
Storage temperature
Damp heat
non operational
IEC/EN 60068-2-3, 93%, 40°C
IEC/EN 60068-2-6, 10...60/60...2000 Hz
IEC/EN 60068-2-27, 11 ms
IEC/EN 60068-2-29, 11 ms
IEC/EN 60068-2-64, 20...500 Hz
Vibration, sinusoidal
Shock
Bump
25 gn
4.9 gn rms
Random vibration
Options
Extended temperature range
Out OK output
–40...71°C, ambient, operating
excludes option i
-9
D
Current sharing
T
Inhibit on output side
Synchronisation
Heat Sink
excludes option D
i
W
B1
www.power-one.com
Edition 6/10.2001
3