DATA SHEET
TECHNICAL DATA:
Input
PARAMETER
Input voltage range.
Input frequency range
Input surge current
Safety ground leakage current
Input current
DESCRIPTION/CONDITION
Universal Input
47 to 400 Hz. (3)
264 Vac (cold start)
120 Vac < 500 uA
120 Vac @ 60 W
230 Vac @ 60 W
90 - 264 Vac
40 A max.
230 Vac < 1000 uA
1.5 A
0.75 A
Output
PARAMETER
Voltage Adjustment
Transient Response
Over Voltage Protection
Short Circuit Protection
Remote Sense
Efficiency
Set Point Tolerance
Rise Time
DESCRIPTION/CONDITION
V1
Main output 50 to 100% load change, 50 Hz,
50% duty cycle, 0.1 A / u Sec, 50/60 Hz
130% Typical
130% Typical
V1
>85%
V1 = ± 3%, V2 & V3 = ± 5%
100 mSec
± 10%
< 10%, recovery time < 5 mSec
0.5 Vdc compensation
Ordering Information
PRODUCT
FAMILY
ABC60-1005G
ABC60-1012G
ABC60-1015G
ABC60-1024G
ABC60-1048G
ABC60-3000G
VOLTS
(VDC)
5.2
12
15
24
48
5.2
12.5
-12.5
5.2
OUTPUT CURRENT
MAX (A)
10.0
5.4
4.33
2.7
1.35
8.0
3.0
0.5
8.0
1.5
0.5
8.0
2.5
0.5
8.0
3.0
0.5
MINIMUM
LOAD (A)
(4)
0
0
0
0
0
0.5
0.1
0.0
0.5
0.1
0.0
0.5
0.1
0.0
1.0
0.1
0.0
RIPPLE &
NOISE
1.25%
1%
1%
1%
1%
1.25%
1%
1%
1.25%
1%
1%
1.25%
1%
1%
1.5%
1%
1%
TOTAL
REGULATION
± 0.8%
± 0.8%
± 0.8%
± 0.8%
± 0.8%
± 0.8%
± 5.3%
± 5.3%
± 0.8%
± 5.3%
± 5.3%
± 0.8%
± 5.3%
± 5.3%
± 0.8%
± 5.3%
± 5.3%
OVP THRESHOLD
130% Typical
130% Typical
130% Typical
130% Typical
130% Typical
130% Typical
130% Typical
ABC60-3001G
23.8
-12.5
5.2
130% Typical
ABC60-3002G
14.6
-16.2
3.3
130% Typical
ABC60-3003G
5.2
-12.8
ABC60 Series
2