DATA SHEET
TECHNICAL DATA:
Input
PARAMETER
Input voltage range
Input frequency range
Input surge current
Safety ground leakage current
Input current
DESCRIPTION/CONDITION
Universal Input
47-63 Hz
230 Vac (cold start)
230 Vac
120 Vac @ 200 W
230 Vac @ 200 W
65 A max.
300 μA max
3.2 A
1.65 A
90 - 264 Vac
120 – 390 Vdc
Output
PARAMETER
Voltage Adjustment
Transient Response
Over Voltage Protection
Over Current Protection
Short Circuit Protection
Over Temperature Protection
Set point tolerance
Rise Time
DESCRIPTION/CONDITION
V1
Main output 50 to 100% load change, 50 Hz,
50% duty cycle, 0.1 A / uSec, 50/60 Hz.
V1
Rated output current
Automatic recovery
Automatic recovery
± 1%
<100 mSec
110° C primary heatsink
± 3%
< 10%, recovery time < 5 mSec
110 to 150% rated max
110 to 150% Typical
Ordering Information
PRODUCT FAMILY
ABC300-1T05G
ABC300-1T12G
ABC300-1T15G
ABC300-1T24G
ABC300-1T30G
ABC300-1T48G
Vfan (all models)
V s/b (all models)
VOLTS
MAX LOAD
MAX LOAD
(VDC) CONVECTION (2) 300 LFM (2)
5
12
15
24
30
48
12
5
28.0 A
15.0 A
12.0 A
7.5 A
6.0
3.75 A
0.5 A
2.0 A
40.0 A
25.0 A
20.0 A
13.54 A
10.83 A
6.77 A
0.5 A
2.0 A
MINIMUM
LOAD (A)
0
0
0
0
0
0
0
0
RIPPLE &
NOISE (4)
2%
2%
2%
2%
2%
2%
CONNECTOR
Screw Terminal
Screw Terminal
Screw Terminal
Screw Terminal
Screw Terminal
Screw Terminal
TOTAL
REGULATION
± 2.5%
± 2.5%
± 2.5%
± 2.5%
± 2.5%
± 2.5%
± 20%
± 5%
Notes:
1.
2.
3.
4.
5.
Peak current rating of 120% of max, < 30 Sec with max of 10% duty cycle.
Combined power from main output, Vfan and Vs/b should not exceed total power rating.
Fan output tolerance is ± 20%. When V1 full load, Vfan needs 20 mA load to be within regulation specification. Peak
current for fan output is 1 A.
Ripple is 2% up to 20% load and less than 1% above 20% load. Output noise measurement is made with a 20 MHz
bandwidth using a 6” twisted pair, terminated with a 10 uF tantalum capacitor in parallel with a 0.1 uF ceramic capacitor.
Specifications are for nominal input voltage, 25° C and max load unless otherwise stated.
ABC300 Series
2
www.power-one.com