ABC200-10XXG Data Sheet
12VDC, 24VDC, 48VDC
Output
Figure 11: Load transient V
O
, 7.5A to 15A (200 us/div),
CH1:
I
O
(5 A/div)
CH2:
V
O
(200 mV/div)
Figure 12: Load transient V
O
, 15A to 7 A (200 us/div)
CH1:
I
O
(5 A/div)
CH2:
V
O
(200 mV/div)
7 PROTECTION
Parameter
Input fuses rating
I
FUSE
V
O OV
OV trigger point
Conditions / Description
Not user accessible, time lag characteristic
ABC200-1012G
ABC200-1024G
ABC200-1012G
ABC200-1012G
V
i
> 90 VAC,
ABC200-1024G
-10 °C <
T
a
< 50 °C
ABC200-1048G
Automatic shut-down
Min
14.0
28.0
53.0
Nom
5.0
15.0
30.0
55.0
18.0
9.0
4.5
105
Max
16.0
32.0
57.0
Unit
A
VDC
VDC
VDC
A
A
A
°C
I
O lim
T
SD
Current limit
Temperature on heat sinks
7.1 OVERVOLTAGE PROTECTION
The AC-DC power supply provides a fixed threshold
overvoltage (OV) protection implemented with a HW
comparator. Once an OV condition has been triggered, the
supply will shut down and latch the fault condition. The
latch can be unlocked by disconnecting the supply from the
AC mains only.
7.2 CURRENT LIMITATION
The main output current limitation will decrease with linear
derating to 50% at 70 ºC if the ambient (inlet) temperature
increases beyond 50 °C (see Figure 13).
Figure 13: Output Current Capacity Derating
BCD.G0201 Rev. AA, 29-Apr-2011
Page 8 / 12