Industrial Environment  
DC/DC Converters < 40W  
IMS6 Series  
Cleaning Agents  
Table 14: Electric strength test voltages  
In order to avoid possible damage, any penetration of  
cleaning fluids has to be prevented, since the power sup-  
plies are not hermetically sealed.  
Characteristic  
Input - Output  
24/48 IMS 6  
Unit  
Electric strength  
test voltage 1 s  
1.2  
1.5  
1.2  
kVrms  
kV DC  
nF  
Protection Degree  
The protection degree of the DC-DC converters is IP 30.  
Coupling  
capacitance  
Isolation  
Insulation resist.  
at 500 V DC  
>100  
M
The electric strength test is performed as factory test in ac-  
cordance with IEC/EN 60950 and UL 1950 and should not  
be repeated in the field. Melcher will not honour any guar-  
antee claims resulting from electric strength field tests.  
Partial discharge  
extinctionvoltage  
Consult factory  
kV  
Table 15: Insulation concept leading to an SELV output circuit  
Conditions Front end  
DC-DC converter  
Result  
Supply  
voltage  
Minimum required grade  
of isolation, to be provided DC output status of the front end  
by the AC-DC front end,  
including mains supplied  
battery charger  
Maximum Minimum required safety  
Measures to achieve the  
specified safety status of the  
output circuit  
Safety status of  
the DC-DC  
converter output  
circuit  
voltage  
output circuit  
from the  
front end 1  
Mains  
250 V AC  
Basic  
60 V  
Earthed SELV circuit 2  
ELV circuit  
Operational insulation, pro-  
vided by the DC-DC converter  
SELV circuit  
Input fuse 3 output suppressor Earthed SELV  
diodes 4, and earthed  
output circuit 2  
circuit  
>60 V  
60 V  
Hazardous voltage  
secondary circuit  
Double or reinforced  
SELV circuit  
Operational insulation, pro-  
SELV circuit  
vided by the DC-DC converter  
1 The front end output voltage should match the specified input voltage range of the DC-DC converter.  
2 The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC/EN 60950.  
3 The installer shall provide an approved fuse (type with the lowest rating suitable for the application) in a non-earthed input line directly  
at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL’s purpose, the fuse needs to be UL-listed. See also:  
Input Fuse.  
4 Each suppressor diode should be dimensioned in such a way, that in the case of an insulation fault the diode is able to limit the output  
voltage to SELV (<60 V) until the input fuse blows (see fig.: Schematic safety concept).  
5 Has to be insulated from earth by double or reinforced insulation according to the relevant safety standard, based on the maximum  
output voltage from the front end.  
10004  
Fuse  
+
~
Mains  
Suppressor  
diode  
AC-DC  
front  
DC-DC  
con-  
Battery  
SELV  
end  
verter  
~
Earth  
connection  
Earth  
connection  
Fig. 23  
Schematic safety concept. Use fuse, suppressor diode  
and earth connection as per table: Safety concept leading  
to an SELV output circuit.  