欢迎访问ic37.com |
会员登录 免费注册
发布采购

40IMX7-05-05-8 参数 Datasheet PDF下载

40IMX7-05-05-8图片预览
型号: 40IMX7-05-05-8
PDF下载: 下载PDF文件 查看货源
内容描述: [IMX7/IMS7 DC-DC Series Data Sheet 7-Watt DC-DC Converters]
分类和应用:
文件页数/大小: 15 页 / 380 K
品牌: POWER-ONE [ POWER-ONE ]
 浏览型号40IMX7-05-05-8的Datasheet PDF文件第7页浏览型号40IMX7-05-05-8的Datasheet PDF文件第8页浏览型号40IMX7-05-05-8的Datasheet PDF文件第9页浏览型号40IMX7-05-05-8的Datasheet PDF文件第10页浏览型号40IMX7-05-05-8的Datasheet PDF文件第11页浏览型号40IMX7-05-05-8的Datasheet PDF文件第13页浏览型号40IMX7-05-05-8的Datasheet PDF文件第14页浏览型号40IMX7-05-05-8的Datasheet PDF文件第15页  
IMX7/IMS7 DC-DC Series Data Sheet  
7-Watt DC-DC Converters  
®
Date: 5.9.07  
110IMX7-05-8 Peak  
Time: 08:00  
PMM 8000 PLUS  
Name: 110_7_05  
Date: 5.9.07  
48IMS7-15-15-8 Peak  
Time: 09:10  
PMM 8000 PLUS  
Name: 48_7_15  
dbμV  
80  
dbμV  
80  
EN 55022 A  
EN 55022 A  
60  
40  
60  
40  
20  
0
20  
0
0.2  
0.5  
1
2
5
10  
20 MHz  
0.2  
0.5  
1
2
5
10  
20 MHz  
Fig. 17  
Fig. 16c  
48IMS7-15-15-8: Typical conducted emissions (peak) at the  
input at Vi nom and Io nom according to EN 55011/22. Output  
leads 0.1 m, twisted. External input capacitor (1 μF ceramic +  
47 μF electrolytic cap).  
110IMX7-05-8: Typical conducted emissions (peak) at the  
input at Vi nom and Io nom according to EN 55011/22. Output  
leads 0.1 m, twisted. External input capacitor (0.15 μF  
ceramic + 4.7 μF electrolytic cap).  
Immunity to Environmental Conditions  
Table 9: Mechanical and climatic stress  
Test Method  
Standard  
Test conditions  
Status  
Cab  
Damp heat  
steady state  
IEC/EN 60068-2-78  
MIL-STD-810D section 507.2  
Temperature:  
Relative humidity:  
Duration:  
40 ±2 °C  
Converter  
not  
operating  
93 +2/-3  
%
56 days  
Ea  
Shock  
(half-sinusoidal)  
IEC/EN 60068-2-271  
MIL-STD-810D section 516.3  
Acceleration amplitude:  
Bump duration:  
100 gn = 981 m/s2  
6 ms  
Converter  
operating  
Number of bumps:  
18 (3 each direction)  
Eb  
Bump  
(half-sinusoidal)  
IEC/EN 60068-2-29  
MIL-STD-810D section 516.3  
Acceleration amplitude:  
Bump duration:  
40 gn = 392 m/s2  
6 ms  
Converter  
operating  
Number of bumps:  
6000 (1000 each direction)  
Fc  
Vibration  
(sinusoidal)  
IEC/EN 60068-2-6  
IEC/EN 60068-2-64  
IEC/EN 60068-2-52  
Acceleration amplitude:  
0.35 mm (10 to 60 Hz)  
Converter  
5 gn = 49 m/s2 (60 to 2000 Hz) operating  
10 to 2000 Hz  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h each axis)  
Fh  
Kb  
Vibration,  
broad-band  
random  
Acceleration spectral density: 0.05 gn2/Hz  
Converter  
operating  
Frequency band:  
Acceleration magnitude:  
Test duration:  
10 to 500 Hz  
4.9 gn rms  
3 h (1 h each axis)  
(digital control)  
Salt mist, cyclic  
(sodium chloride  
NaCl solution)  
Concentration:  
Duration:  
Storage:  
Storage duration:  
Number of cycles:  
5% (30 °C)  
Converter  
not  
operating  
2 h per cycle  
40 °C, 93% rel. humidity  
22 h per cycle  
3
1
Covers also EN 50155/EN 61373 category 1, class B, body mounted (= chassis of coach)  
Temperatures  
Table 10: Temperature specifications, valid for air pressure of 800 to 1200 hPa (800 to 1200 mbar)  
Temperature  
-9  
-8  
Characteristics  
Conditions  
Operational 1  
min  
–40  
–40  
max  
71  
min  
–40  
–40  
max  
85  
Unit  
TA  
TC  
Ambient temperature  
°C  
Case temperature  
95  
105  
TS  
Storage temperature  
Non operational  
–55  
100  
–55  
105  
1
See Thermal Considerations  
BCD20007-G Rev AD, 4-Nov-09  