Industrial Environment  
DC/DC Converters < 40W  
IMS6 Series  
Immunity to Environmental Conditions  
Table 8: Mechanical stress  
Test Method  
Standard  
Test Conditions  
Status  
2
Ca  
Ea  
Eb  
Fc  
Damp heat  
steady state  
IEC/DIN IEC 60068-2-3  
MIL-STD-810D section 507.2 Relative humidity:  
Duration:  
Temperature:  
40  
C
%
Unit not  
operating  
93 +2/-3  
56 days  
Shock  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-27  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
100 gn = 981 m/s2  
6 ms  
18 (3 each direction)  
Unit  
operating  
Bump  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-29  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
40 gn = 392 m/s2  
6 ms  
6000 (1000 each direction)  
Unit  
operating  
Vibration  
(sinusoidal)  
IEC/EN/DIN EN 60068-2-6  
MIL-STD-810D section 514.3  
Acceleration amplitude:  
0.35 mm (10...60 Hz)  
5 gn = 49 m/s2 (60...2000 Hz) operating  
10...2000 Hz  
Unit  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h each axis)  
Fda Random vibration IEC 60068-2-35  
Acceleration spectral density: 0.05 gn2/Hz  
Unit  
wide band  
reproducibility  
high  
Frequency band:  
Acceleration magnitude:  
Test duration:  
10...500 Hz  
4.9 gn rms  
3 h (1 h each axis)  
operating  
Kb  
Salt mist, cyclic  
(sodium chloride  
NaCl solution)  
IEC/EN/DIN IEC 60068-2-52  
Concentration:  
Duration:  
Storage:  
Storage duration:  
Number of cycles:  
5% (30 C)  
Unit not  
operating  
2 h per cycle  
40 C, 93% rel. humidity  
22 h per cycle  
3
Table 9: Temperature specifications, valid for air pressure of 800...1200 hPa (800...1200 mbar)  
Temperature  
Standard -9  
max  
Characteristics  
Conditions  
Operational 2  
min  
–40  
–40  
–40  
Unit  
C
TA  
TC  
TS  
Ambient temperature 1  
71  
Case temperature  
Storage temperature 1  
100  
100  
Non operational  
1 MIL-STD-810D section 501.2 and 502.2  
2 See Thermal Considerations  
Table 10: MTBF and device hours  
MTBF  
Ground Benign  
Ground Fixed  
Ground Mobile  
TC = 50 C  
Device Hours 1  
MTBF acc. to MIL-HDBK-217F  
48IMS6-05-9  
TC = 40 C  
TC = 40 C  
349'000 h  
TC = 70 C  
124'000 h  
2'651'000 h  
119'000 h  
1 Statistical values, based on an average of 4300 working hours per year and in general field use  
Edition 1 06.00