Industrial Environment  
DC/DC Converters < 40W  
IMS6 Series  
Safety and Installation Instructions  
Installation Instruction  
Table 12: Pin allocation for K pinout (option K)  
Installation of the DC-DC converters must strictly follow the  
national safety regulations in compliance with the enclo-  
sure, mounting, creepage, clearance, casualty, markings  
and segregation requirements of the end-use application.  
Pin  
1
Single output units  
Dual output units  
Vi+  
n.c.  
-
Vi+  
-
2
10  
11  
12  
13  
15  
24  
Go  
Go  
-
Connection to the system shall be made via a printed circuit  
board according to: Mechanical Data.  
-
The units should be connected to a secondary circuit.  
Vo–  
Vo+  
-
Check for hazardous voltages before altering any connec-  
tions.  
Vo–  
Vo+  
Vi–  
Do not open the module.  
Vi–  
Ensure that a unit failure (e.g. by an internal short-circuit)  
does not result in a hazardous condition. See also: Safety  
of operator accessible output circuit.  
Table 13: Pin allocation for SMD pinout (option M)  
Pin  
Single output units  
Dual output units  
Table 11: Pin allocation for standard industrial pinout  
1
2
Vi+  
Vi–  
Vi+  
Vi–  
Pin  
2
Single output units  
Dual output units  
Vi–  
Vi–  
n.c.  
-
Vi–  
Vi–  
-
3
Vi–  
Vi–  
3
9
n.c.  
n.c.  
Vo–  
Vo–  
Vo+  
Vo+  
Vo+  
Vo–  
Vi+  
n.c.  
Go  
10  
11  
14  
16  
22  
23  
10  
11  
12  
13  
14  
15  
16  
22  
23  
Vo–  
Vo+  
Go  
Vi+  
Vi+  
Vo–  
Vo–  
Vo–  
Vo+  
Vo+  
Go  
Vo+  
Vo–  
Vi+  
Vi+  
10013  
Vi+  
24  
13  
Vi+  
Vi+  
Bottom view  
12  
1
24  
Vi-  
Vi+  
Fig. 22  
Pin numbering  
Input Fuse  
Safety of operator accessible output circuits  
To prevent excessive current flowing through the input sup-  
ply line in case of a short-circuit across the converter input  
an external fuse should be installed in a non earthed input  
supply line. We recommend a fast acting fuse F0.5A  
If the output circuit of a DC-DC converter is operator acces-  
sible, it shall be an SELV circuit according to IEC/EN 60950  
related safety standards  
The insulation concept table below shows some possible  
installation configurations, compliance with which causes  
the output circuit of the DC-DC converter to be an SELV cir-  
cuit according to IEC/EN 60950 up to a configured output  
voltage (sum of nominal voltages if in series or +/– configu-  
ration) of 46 V.  
for 24 IMS 6 and F0.315A  
for 48 IMS 6 types.  
Standards and approvals  
All DC-DC converters are UL recognized according to UL  
1950, UL recognized for Canada to CAN/CSA C22.2 No.  
950-95 and LGA approved to IEC/EN 60950 standards.  
However, it is the sole responsibility of the installer to en-  
sure the compliance with the relevant and applicable safety  
regulations. More information is given in: Technical Infor-  
mation: Safety.  
The units have been evaluated for:  
• Building in  
• Supplementary insulation input to output, based on their  
maximum input voltage  
• The use in a pollution degree 2 environment  
• Connecting the input to a secondary circuit which is sub-  
ject to a maximum transient rating of 1500 V.  
The DC-DC converters are subject to manufacturing sur-  
veillance in accordance with the above mentioned UL,  
CSA, EN and ISO 9001 standards.  
Edition 1 06.00