IMX35 Series Data Sheet
35 Watt Quad-Output DC-DC Converters
Conducted emission according to EN 55011/55022, class A,
can be achieved by adding an external common mode choke
and an additional ceramic capacitor. The filter components
should be placed as close as possible to the input of the
converter; see figure 15.
Table 12: Input filter components
Model
20IMX35
40IMX35
70IMX35
110IMX35
Common mode choke
L
1
(Murata)
70 µH / 3.6 A, PLH10AN7003R6P2
160 µH / 2.1 A, PLH10AN1612R1P2
290 µH / 1.2 A, PLH10AN2911R2P2
370 µH / 1.0 A, PLH10AN3711R0P2
Ceramic cap
C
1
4.7 µF / 50 V
2.2 µF / 100 V
1 µF / 200 V
1 µF / 200 V
07114c
+
L
i
C
i
Vi+
Converter
Vi–
–
Fig. 15
External filter circuitry
Immunity to Environmental Conditions
Table 13: Mechanical and climatic stress
Test method
Cab
Damp heat
steady state
Salt mist test
sodium chloride
(NaCl) solution
2
Bump
(half-sinusoidal)
Vibration
(sinusoidal)
Standard
IEC/EN 60068-2-78
MIL-STD-810D section 507.2
EN 50155:2007
sect. 12.2.10
class ST3
2
IEC/EN 60068-2-29
MIL-STD-810D section 516.3
IEC/EN 60068-2-6
MIL-STD-810D section 514.3
Test conditions
Temperature:
Relative humidity:
Duration:
Temperature:
Duration:
Acceleration amplitude:
Bump duration:
Number of bumps:
Acceleration amplitude:
Frequency (1 Oct/min):
Test duration:
Fh
Random vibration
broad-band
(digital control) and
guidance
Shock
(half-sinusoidal)
Shock
IEC/EN 60068-2-64
Acceleration spectral density:
Frequency band:
Acceleration magnitude:
Test duration:
Acceleration amplitude:
Bump duration:
Number of bumps:
Acceleration amplitude:
Bump duration:
Number of bumps:
Acceleration spectral density:
Frequency band:
Acceleration magnitude:
Test duration:
40
±2
°C
93
+2/-3
%
56 days
35
±2
°C
48 h
25 g
n
= 245 m/s
2
6 ms
6000 (1000 in each direction)
0.35 mm (10 – 60 Hz)
5 g
n
= 49 m/s
2
(60 - 2000 Hz)
10 – 2000 Hz
7.5 h (2.5 h in each axis)
0.05 g
n2
/Hz
8 – 500 Hz
4.9 g
rms
1.5 h (0.5 h in each axis)
50 g
n
= 490 m/s
2
11 ms
18 (3 in each direction)
5.1 g
n
30 ms
18 (3 in each direction)
0.02 g
n2
/Hz
5 – 150 Hz
0.8 g
n rm s
15 h (5 h in each axis)
Status
Converter
not
operating
Converter
not
operating
Converter
operating
Converter
operating
--
Eb
Fc
Converter
operating
Ea
IEC/EN 60068-2-27
MIL-STD-810D section 516.3
EN 50155:2007 sect. 12.2.11
EN 61373 sect. 10, class B,
body mounted
1
EN 50155:2007 sect. 12.2.11
EN 61373 sect. 8 and 9,
Body mounted
1
Converter
operating
Converter
operating
Converter
operating
--
--
Simulated long life
testing at
increased random
vibration levels
1
2
Body mounted = chassis of a railway coach
Models without option Z
BCD20009-G Rev AC, 06-May-2013
Page 12 of 15