IMX35 Series Data Sheet
35 Watt Quad-Output DC-DC Converters
Electrical Output Data
General conditions:
– T
A
= 25 °C, unless
T
C
is specified
– Pins 8 (shutdown or i), 6 (W), 5 (Trim or Trim1), and 1 (PUL) left open-circuit (not connected), unless specified.
Table 6: Output data
per double-output power train
(Vo1/Vo4 or Vo2/Vo3; each power train has 2 outputs)
Output
Characteristics
V
o1
V
o2
I
o nom
Output voltage
Output current
Conditions
V
i nom
I
o
= 0.5
I
o nom
20IMX
V
i min
to
V
i max
40IMX
70IMX
110IMX
I
oL
Current limit
1
20IMX
V
i nom
,
T
C
= 25 °C
V
o
= 93%
V
o nom
40IMX
70IMX
110IMX
∆V
o
∆V
o l
V
o1/2
V
o L
C
o ext
V
o d
t
d
α
Vo
Line regulation
Load regulation
Output voltage noise
Output overvoltage limit.
4
Admissible capacitive load
per power train
5
Dynamic
load
regulation
Voltage deviat.
Recovery time
V
i min
to
V
i max
,
I
o nom
V
i nom
I
o
= (0.1 to 1)
I
o nom
V
i min
to
V
i max
I
o
=
I
o nom
Min. load 1%
produced after 2011
V
i nom
I
o nom
1
/
2
I
o nom
V
i min
to
V
i max
I
o
= (0.1 to 1)
I
o nom
2
3
2x5V
min
4.95
4.94
2 × 1.35
2 × 1.4
2 × 1.4
2 × 1.4
3.5
3.8
3.8
3.8
±1
±3
80
40
115
0
130
6000
±250
0.75
±0.02
115
0
typ
max
5.05
5.06
2 x 12 V
min
11.88
11.86
2 × 0.65
2 × 0.70
2 × 0.70
2 × 0.70
1.8
2.0
2.0
2.0
±1
±3
120
60
130
680
± 480
0.75
±0.02
115
0
typ
max
12.12
12.14
min
2 x 15 V
typ
max
15.15
15.18
2 × 0.55
2 × 0.60
2 × 0.60
2 × 0.60
1.5
1.7
1.7
1.7
±1
±3
150
70
130
470
±520
0.75
±0.02
14.85
14.82
Unit
VDC
A
%
mV
pp
%
µF
mV
ms
%/K
Temperature coefficient
∆V
o
/∆T
C
1
2
3
4
5
Both outputs of each power train connected in parallel. The current limit is primary side controlled. In the event of a sustained overload
condition, the thermal protection may cause the converter to shut down (restart on cool-down).
BW = 20 MHz, measured with an external capacitor of 1 µF across the output pins.
Measured with a probe according to EN 61204
The overvoltage protection is via a primary side second regulation loop, not tracking with Trim control.
Sum of the capacities on both outputs of each power train
BCD20009-G Rev AC, 06-May-2013
Page 6 of 15