TISP61089  
DUAL FORWARD-CONDUCTING P-GATE THYRISTORS  
PROGRAMMABLE OVERVOLTAGE PROTECTORS  
NOVEMBER 1995 - REVISED FEBRUARY 1998  
Second level tests have a low source resistance and the current levels are dependent on the TISP61089  
series resistor value. The two stepped lines at the top of Figure 8 are for the 25 and 40 series resistor  
cases. If the full current-time durations occur the equipment will fail the wiring simulator test. The MDQ 1-6/  
10A fusing characteristic is also shown in Figure 8. The TISP61089 series overcurrent protection must  
operate before the MDQ 1-6/10A fuses, so this represents another boundary condition in the selection of the  
overcurrent protector.  
MAXIMUM RMS CURRENT  
vs  
TIME  
AI6XAK  
30  
20  
Second Level Tests - 25  
Second Level Tests - 40  
10  
7
5
3
2
MDQ 1-6/10A Fuse  
1
0.7  
0.5  
0.3  
0.2  
First Level Tests - 25 & 40  
100  
0.1  
0.01  
0.1  
1
10  
1000  
Time - s  
Figure 8. ‘1089 MAXIMUM TEST CURRENT LEVEL  
Figure 9 summarises these boundary conditions. The highest current levels that can flow are influenced by  
the TISP61089 series resistance. After one second the maximum current-time boundary becomes set by the  
MDQ 1-6/10A fusing characteristic. Fusible overcurrent protectors cannot operate at first level current levels.  
Figure 9 shows two other curves. The lower one is the TISP61089 rated current. The overcurrent protector  
should not allow current-time durations greater than this otherwise the TISP61089 may fail. If second level  
failure is acceptable then the overcurrent protector must operate before the TISP61089 package limit is  
reached.  
The TISP61089 a.c. ratings are worse case values when the device is mounted on the minimal sized PCB  
used for measuring thermal resistance. Typical PCBs would give a 25% increase in the rated currents for  
periods above 0.1 s.  